居家透析患者体验测量工具的评价与测量性能
本研究在美国30家透析机构中测试新开发的26条目居家透析照护体验调查,495例腹膜透析或居家血透患者完成至少一次调查,应答率36%。分析支持一个12条目的「居家透析照护质量与运营」综合量表,内部一致性信度Cronbach α=0.85,与总体员工评分和中心评分强相关,重测信度良好。
要点
- 该调查含26条目,包括一个12条目综合量表和两个总体评分。
- 综合量表内部一致性Cronbach α=0.85,重测ICC为0.74。
- 综合量表与总体员工评分r=0.73、总体中心评分r=0.70。
核心结论
- 居家透析照护体验调查是包含一个综合量表和两个总体评分的26条目工具,可用于评估居家透析患者照护体验。
研究设计与样本
- 在美国30家透析机构中,通过邮件和电话调查方式接触1372例腹膜透析或居家血透患者。
- 495例符合条件患者完成至少一次调查,应答率36%;其中49例用西班牙语完成,61例在30天内完成第二次调查。
主要发现
- 除一个条目在最高响应选项上超过90%外,未发现显著的地板或天花板效应。
- 分析支持一个12条目的综合量表「居家透析照护质量与运营」,Cronbach α=0.85。
- 该量表与总体员工评分r=0.73、总体中心评分r=0.70强相关。
- 患者人口学和透析机构特征与综合量表评分或总体评分无一致关联。
- 重测组中综合量表ICC为0.74,总体员工评分ICC为0.88,总体中心评分ICC为0.90。
临床怎么用
- 该26条目调查可用于评估居家透析患者照护体验,包含一个综合量表和两个总体评分。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: No previously validated patient-reported experience measures exist for use among patients undergoing home dialysis. We tested the Home Dialysis Care Experience survey, a newly developed 26-item experience measure, among patients from 30 dialysis facilities in the United States. METHODS: Using mail and telephone survey modalities, we approached 1372 patients treated with peritoneal dialysis or home hemodialysis for participation. Using the results from completed surveys, we evaluated item calibration by assessing item floor and ceiling effects. We tested three sets of composite scores and used factor analysis to assess model fit for each. We evaluated associations of composite scores with global ratings and separately with patient and dialysis facility characteristics. Finally, we measured test-retest reliability in patients who completed the survey at two separate time points. RESULTS: Overall, 495 eligible patients completed at least one survey (response rate 36%). Of these, 49 completed the survey in Spanish and 61 completed a second survey within 30 days. We did not detect significant floor or ceiling effects, except for one item that demonstrated >90% responses at the top response option. Analyses supported one 12-item composite scale with high internal consistency reliability: Quality of Home Dialysis Care and Operations (Cronbach alpha=0.85). This scale strongly correlated with overall staff rating ( r =0.73) and overall center rating ( r =0.70). Patient demographic and dialysis facility characteristics were not consistently associated with composite scale scores or overall staff or center ratings. Intraclass correlation coefficients in the test-retest population were 0.74 for the Quality scale, 0.88 for overall staff rating, and 0.90 for overall center rating. CONCLUSIONS: The Home Dialysis Care Experience survey is a 26-item measure that includes one composite scale and two global rating scores and is an informative tool to evaluate patient experience of care for home dialysis.
引用
- Rivara MB, Prince DK, Leuther KK, et al. Evaluation and Measurement Properties of a Patient-Reported Experience Measure for Home Dialysis. Clin J Am Soc Nephrol. 2024. PMID: 38261328. doi:10.2215/CJN.0000000000000429
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。