文献速递血液净化与透析

多层面干预降低血透导管功能障碍发生率:全国阶梯楔形整群随机试验

Effect of a Multifaceted Intervention on the Incidence of Hemodialysis Catheter Dysfunction in a National Stepped-Wedge Cluster Randomized Trial.
PubMed 文献 · Kidney Int Rep · 2023-07-27

该研究为REDUCCTION阶梯楔形整群随机试验的事后分析,覆盖37个澳大利亚肾脏病服务中心、6361名参与者、9872根导管,旨在评估促进循证导管置入与管理实践的多层面干预是否降低导管功能障碍(因透析血流量不足而拔管)发生率。结果显示,校正日历时间后干预期服务范围导管功能障碍发生率较基线期降低33%(IRR=0.67,95%CI 0.50-0.89,P=0.006),隧道式带 cuff 导管结果一致(校正IRR=0.68,95%CI 0.49-0.94)。

要点

  • 干预期导管功能障碍粗发生率为0.68例/1000导管日,基线期为0.91例/1000导管日。
  • 校正日历时间后,干预期服务范围导管功能障碍发生率较基线期降低33%(IRR=0.67,95%CI 0.50-0.89,P=0.006)。
  • 隧道式带cuff导管占75%(n=7403),其校正IRR=0.68(95%CI 0.49-0.94),结果与总体一致。

核心结论

  • 促进循证导管护理的多层面干预可能预防导管功能障碍,患者因素是事件变异的重要来源。

研究设计与样本

  • REDUCCTION全国阶梯楔形整群随机试验的事后分析,涵盖37个澳大利亚肾脏病服务中心、6361名参与者、9872根导管。
  • 干预措施为促进一套血透导管置入与管理的循证实践。
  • 主要结局为因透析血流量不足而拔管所定义的导管功能障碍。

主要发现

  • 共873根血透导管因功能障碍被拔除,累计1.12百万导管日。
  • 基线期粗发生率为0.91例/1000导管日,干预期为0.68例/1000导管日。
  • 校正日历时间后,干预期服务范围导管功能障碍发生率较基线期降低33%(IRR=0.67,95%CI 0.50-0.89,P=0.006)。
  • 隧道式带cuff导管(占75%,n=7403;占97.4%导管暴露时间;占88.2%事件,n=770)校正IRR=0.68(95%CI 0.49-0.94)。
  • 在存活6个月的隧道式导管中(占隧道式导管的21.5%),导管功能障碍事件数无法解释的变异有2%至5%归因于服务层面差异,18%至36%归因于患者层面差异。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Effective strategies to prevent hemodialysis (HD) catheter dysfunction are lacking and there is wide variation in practice. METHODS: In this post hoc analysis of the REDUcing the burden of dialysis Catheter ComplicaTIOns: a national (REDUCCTION) stepped-wedge cluster randomized trial, encompassing 37 Australian nephrology services, 6361 participants, and 9872 catheters, we investigated whether the trial intervention, which promoted a suite of evidence-based practices for HD catheter insertion and management, reduced the incidence of catheter dysfunction, which is defined by catheter removal due to inadequate dialysis blood flow. We also analyzed outcomes among tunneled cuffed catheters and sources of event variability. RESULTS: A total of 873 HD catheters were removed because of dysfunction over 1.12 million catheter days. The raw incidence was 0.91 events per 1000 catheter days during the baseline phase and 0.68 events per 1000 catheter days during the intervention phase. The service-wide incidence of catheter dysfunction was 33% lower during the intervention after adjustment for calendar time (incidence rate ratio = 0.67; 95% confidence interval [CI], 0.50-0.89; P = 0.006). Results were consistent among tunneled cuffed catheters (adjusted incidence rate ratio = 0.68; 95% CI, 0.49-0.94), which accounted for 75% of catheters (n = 7403), 97.4% of catheter exposure time and 88.2% of events (n = 770). Among tunneled catheters that survived for 6 months (21.5% of tunneled catheters), between 2% and 5% of the unexplained variation in the number of catheter dysfunction events was attributable to service-level differences, and 18% to 36% was attributable to patient-level differences. CONCLUSION: Multifaceted interventions that promote evidence-based catheter care may prevent dysfunction, and patient factors are an important source of variation in events.

来源:Kidney Int Rep,查看原文。版权归原作者所有。

引用

  1. Lazarus B, Kotwal S, Gallagher M, et al. Effect of a Multifaceted Intervention on the Incidence of Hemodialysis Catheter Dysfunction in a National Stepped-Wedge Cluster Randomized Trial. Kidney Int Rep. 2023. PMID: 37849996. doi:10.1016/j.ekir.2023.07.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。