该研究采用机器学习方法比较仅用血肌酐(SCr)标准与联合尿量(UO)标准预测急性肾损伤(AKI)的差异,构建13个预测模型并在16个风险评估任务上评估。结果显示入住ICU第一周内仅用SCr标准时AKI患病率为29%,联合UO标准后升至60%,且仅用实验室数据在仅SCr标准下预测性能与全特征模型相近,但联合UO时则不足。
要点
- 入住ICU第一周内仅用SCr标准AKI患病率为29%,联合UO标准后升至60%。
- 仅用实验室数据在仅SCr标准下AUROC与全特征模型相近,联合UO时则不足。
- SCr与UO标准不应视为AKI分期的等效标准,UO标准在风险评估中重要且必要。
核心结论
- SCr与UO标准不应被视为AKI分期的等效标准,UO标准在AKI风险评估中具有重要性和必要性。
研究设计与样本
- 应用机器学习方法评估13个由不同特征类别组成的预测模型在16个风险评估任务上的性能,其中一半任务仅用SCr标准,一半任务联合SCr与UO标准。
主要发现
- 入住ICU第一周内,仅用SCr标准时任何AKI的患病率为29%,联合UO标准后升至60%。
- 在仅用SCr标准下,仅用实验室数据的预测性能与全特征模型相近,例如入住ICU 1天后48小时时间窗内AKI的AUROC(95%CI)为0.83(0.82,0.84) vs 0.84(0.83,0.85)。
- 在联合UO标准时,仅用实验室数据的预测性能不足,相应AUROC(95%CI)为0.75(0.74,0.76) vs 0.84(0.83,0.85)。
- 联合UO与SCr标准可显著识别更多AKI患者,且有无UO时特征类型的预测重要性不同。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Due to the convenience of serum creatinine (SCr) monitoring and the relative complexity of urine output (UO) monitoring, most studies have predicted acute kidney injury (AKI) only based on SCr criteria. This study aimed to compare the differences between SCr alone and combined UO criteria in predicting AKI. METHODS: We applied machine learning methods to evaluate the performance of 13 prediction models composed of different feature categories on 16 risk assessment tasks (half used only SCr criteria, half used both SCr and UO criteria). The area under receiver operator characteristic curve (AUROC), the area under precision recall curve (AUPRC) and calibration were used to assess the prediction performance. RESULTS: In the first week after ICU admission, the prevalence of any AKI was 29% under SCr criteria alone and increased to 60% when the UO criteria was combined. Adding UO to SCr criteria can significantly identify more AKI patients. The predictive importance of feature types with and without UO was different. Using only laboratory data maintained similar predictive performance to the full feature model under only SCr criteria [e.g. for AKI within the 48-h time window after 1 day of ICU admission, AUROC (95% confidence interval) 0.83 (0.82, 0.84) vs 0.84 (0.83, 0.85)], but it was not sufficient when the UO was added [corresponding AUROC (95% confidence interval) 0.75 (0.74, 0.76) vs 0.84 (0.83, 0.85)]. CONCLUSIONS: This study found that SCr and UO measures should not be regarded as equivalent criteria for AKI staging, and emphasizes the importance and necessity of UO criteria in AKI risk assessment.
引用
- Wu L, Li Y, Zhang X, et al. Prediction differences and implications of acute kidney injury with and without urine output criteria in adult critically ill patients. Nephrol Dial Transplant. 2023. PMID: 37019835. doi:10.1093/ndt/gfad065
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。