基于人群的尿肌酐排泄限度
研究利用慢性肾功能不全队列(CRIC)3582例、MDRD研究814例、杰克逊心脏研究(JHS)1010例和PREVEND研究8536例参与者的24小时尿数据,构建预测24小时尿肌酐排泄量的模型,并在4599例验证队列中评估。模型包含性别特异的体重、身高和年龄项(R²=0.328),验证队列中位偏倚为+4.3 mg肌酐/天(95%CI -5.6, +13.3 mg/天),82%的观测值在预测值±30%以内。结论认为该限度是评估定时尿采集充分性最有效和最具代表性的数据。
要点
- 预测24小时尿肌酐排泄量的模型包含性别特异的体重、身高和年龄项(R²=0.328)。
- 验证队列中位偏倚为+4.3 mg肌酐/天(95%CI -5.6, +13.3 mg/天)。
- 82%的观测值在预测模型±30%以内。
核心结论
- 基于人群衍生的尿肌酐排泄限度是评估定时尿采集充分性最有效和最具代表性的数据。
研究设计与样本
- 使用CRIC研究3582例、MDRD研究814例、JHS 1010例和PREVEND研究8536例参与者的协变量和24小时尿数据。
- 以体重、身高、年龄、性别和血清肌酐浓度为候选预测因子,采用赤池信息准则、R²值和偏差评估模型。
- 通过残差分析评估拟合模型的偏倚和精度,并在排除可能无效的尿样本前后比较24小时肌酐清除率与125I-碘他拉酸盐清除率的一致性。
主要发现
- 在9199例发现队列成员中,最佳拟合模型包含性别特异的体重、身高和年龄项(R²=0.328)。
- 该模型在4599例验证队列成员中的中位偏倚为+4.3 mg肌酐/天(95%CI -5.6, +13.3 mg/天)。
- 82%的观测值在预测模型±30%以内。
- 血清肌酐浓度仅轻微改善模型精度,但降低了晚期慢性肾脏病(CKD)患者的偏倚。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The validity of a timed urine collection is typically judged by measurement of urine creatinine excretion, but prevailing limits may be unreliable. We sought to empirically derive population-based limits of excretion for evaluating the validity of a timed urine collection. METHODS: Covariate and 24-hour urine data were obtained from 3582 participants in the Chronic Renal Insufficiency Cohort (CRIC) study, 814 participants in the Modification of Diet in Renal Disease (MDRD) study, 1010 participants in the Jackson Heart Study (JHS), and 8536 participants in the Prevention of Renal Vascular End Stage Disease (PREVEND) study. Weight, height, age, sex, and serum creatinine concentrations were evaluated as potential predictors of urine creatinine excretion using Akaike Information Criteria, R-squared values, and deviance. Bias and precision of the fitted models were assessed by analyses of residuals. Agreement between 24-hour creatinine clearance and 125I-iothalamate clearance was assessed before and after exclusion of potentially invalid urine samples. RESULTS: A best-fitting model to predict 24-hour urine creatinine excretion among the 9199 discovery cohort members included sex-specific terms for weight, height, and age (R-squared = 0.328). This model had a median bias of +4.3 mg creatinine/day (95% confidence interval -5.6, +13.3 mg/day) in 4599 validation cohort members, and 82% of observed values were within 30% of predicted model. Serum creatinine concentrations only marginally improved model precision but reduced bias in persons with advanced chronic kidney disease (CKD). CONCLUSION: The limits of urine creatinine excretion derived here represent the most valid and representative data for appraising the adequacy of a timed urine collection.
引用
- Kestenbaum B, Ix JH, Gansevoort R, et al. Population-Based Limits of Urine Creatinine Excretion. Kidney Int Rep. 2022. PMID: 36531868. doi:10.1016/j.ekir.2022.08.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。