文献速递慢性肾脏病遗传性与小管间质肾病

基于深度学习的常染色体显性多囊肾病肾脏及外生性囊肿自动分割方法

A Deep Learning Approach for Automated Segmentation of Kidneys and Exophytic Cysts in Individuals with Autosomal Dominant Polycystic Kidney Disease.
PubMed 文献 · J Am Soc Nephrol · 2022-06-29

本研究开发了一种全自动分割方法,利用3D U-Net深度学习网络在常染色体显性多囊肾病(ADPKD)患者的腹部T2加权磁共振图像上选择性分割肾脏区域并排除外生性囊肿。研究使用210例ADPKD患者图像,其中157例用于训练网络、53例用于测试。自动分割与人工参考方法在测试集上表现出优异的几何一致性,Dice相似系数为0.962±0.018,组内相关系数为0.9994(95%CI 0.9991至0.9996;P<0.001),最小偏倚为-2.424 ml(95%一致性界限 -49.80至44.95)。作者认为该方法测量排除外生性囊肿的肾脏总体积(TKV)的准确性与人类专家相似,可能有助于需要自动计算TKV以评估ADPKD进展和治疗反应的临床研究。

要点

  • 全自动深度学习分割方法可测量排除外生性囊肿的肾脏总体积,测试集Dice相似系数为0.962±0.018。
  • 自动与人工方法的组内相关系数为0.9994(95%CI 0.9991至0.9996;P<0.001),最小偏倚为-2.424 ml。
  • 作者认为该技术可能有助于需要自动计算TKV以评估ADPKD进展和治疗反应的临床研究。

核心结论

  • 作者开发了一种全自动分割方法测量排除外生性囊肿的肾脏总体积,其准确性与人类专家相似。
  • 作者认为该技术可能有助于需要自动计算TKV以评估ADPKD进展和治疗反应的临床研究。

研究设计与样本

  • 研究使用210例ADPKD患者的腹部T2加权磁共振图像,分为157例训练组和53例测试组。
  • 采用3D U-Net架构并使用数据集指纹,通过K折交叉验证训练网络,157例中80%用于训练、20%用于验证。
  • 使用Dice相似系数、组内相关系数和Bland-Altman分析评估自动分割方法与人工方法相比的性能。

主要发现

  • 自动与人工参考方法在测试数据集上表现出优异的几何一致性,Dice相似系数为0.962±0.018。
  • 测试集肾脏体积范围为178.9至2776.0 ml(均值±标准差 1058.5±706.8 ml),外生性囊肿体积范围为113.4至2497.6 ml(均值±标准差 549.0±559.1 ml)。
  • 组内相关系数为0.9994(95%CI 0.9991至0.9996;P<0.001),最小偏倚为-2.424 ml(95%一致性界限 -49.80至44.95)。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total kidney volume (TKV) is an important imaging biomarker in autosomal dominant polycystic kidney disease (ADPKD). Manual computation of TKV, particularly with the exclusion of exophytic cysts, is laborious and time consuming. METHODS: We developed a fully automated segmentation method for TKV using a deep learning network to selectively segment kidney regions while excluding exophytic cysts. We used abdominal T2 -weighted magnetic resonance images from 210 individuals with ADPKD who were divided into two groups: one group of 157 to train the network and a second group of 53 to test it. With a 3D U-Net architecture using dataset fingerprints, the network was trained by K-fold cross-validation, in that 80% of 157 cases were for training and the remaining 20% were for validation. We used Dice similarity coefficient, intraclass correlation coefficient, and Bland-Altman analysis to assess the performance of the automated segmentation method compared with the manual method. RESULTS: The automated and manual reference methods exhibited excellent geometric concordance (Dice similarity coefficient: mean±SD, 0.962±0.018) on the test datasets, with kidney volumes ranging from 178.9 to 2776.0 ml (mean±SD, 1058.5±706.8 ml) and exophytic cysts ranging from 113.4 to 2497.6 ml (mean±SD, 549.0±559.1 ml). The intraclass correlation coefficient was 0.9994 (95% confidence interval, 0.9991 to 0.9996; P<0.001) with a minimum bias of -2.424 ml (95% limits of agreement, -49.80 to 44.95). CONCLUSIONS: We developed a fully automated segmentation method to measure TKV that excludes exophytic cysts and has an accuracy similar to that of a human expert. This technique may be useful in clinical studies that require automated computation of TKV to evaluate progression of ADPKD and response to treatment.

来源:J Am Soc Nephrol,查看原文。版权归原作者所有。

引用

  1. Kim Y, Tao C, Kim H, et al. A Deep Learning Approach for Automated Segmentation of Kidneys and Exophytic Cysts in Individuals with Autosomal Dominant Polycystic Kidney Disease. J Am Soc Nephrol. 2022. PMID: 35768178. doi:10.1681/ASN.2021111400

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。