PodoCount:一种稳健的全自动全切片足细胞定量工具
PodoCount是一种开源云端计算工具,用于对免疫组化标记的足细胞核进行全自动全切片定量。在135个小鼠全肾切片(6种疾病模型)和45例糖尿病肾病患者人肾活检标本中验证,足细胞核识别准确率0.98,分割敏感度0.85、特异度0.99,计数误差不超过每肾小球1个足细胞。足细胞特异性图像特征可显著预测疾病状态、蛋白尿和临床结局。
要点
- PodoCount自动定量足细胞,识别准确率0.98,分割敏感度0.85、特异度0.99。
- 足细胞计数误差不超过每肾小球1个足细胞。
- 足细胞特异性图像特征可显著预测疾病状态、蛋白尿和临床结局。
核心结论
- PodoCount能在多种小鼠疾病模型和人肾活检标本中实现高性能足细胞定量。
- 所得图像特征与相关元数据和结局显著相关。
- 该云端工具为千兆像素级全切片图像提供标准化的自动足细胞定量方法。
研究设计与样本
- 获取足细胞核标记免疫组化联合过碘酸-雪夫复染的全切片图像。
- 数据集包括来自6种疾病模型的小鼠全肾切片(n=135)和糖尿病肾病患者的人肾活检标本(n=45)。
- 在分割的肾小球内提取足细胞并应用图像分析计算足细胞耗竭和核形态学指标。
- 通过计算性能评估和统计检验验证足细胞定量及相关图像特征。
- PodoCount以开源云端计算工具形式发布。
主要发现
- 与现有方法基准比较,PodoCount产生高度准确的足细胞定量。
- 足细胞核轮廓识别准确率0.98,分割敏感度0.85、特异度0.99。
- 足细胞计数误差不超过每肾小球1个足细胞。
- 足细胞特异性图像特征可显著预测疾病状态、蛋白尿和临床结局。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Podocyte depletion is a histomorphologic indicator of glomerular injury and predicts clinical outcomes. Podocyte estimation methods or podometrics are semiquantitative, technically involved, and laborious. Implementation of high-throughput podometrics in experimental and clinical workflows necessitates an automated podometrics pipeline. Recognizing that computational image analysis offers a robust approach to study cell and tissue structure, we developed and validated PodoCount (a computational tool for automated podocyte quantification in immunohistochemically labeled tissues) using a diverse data set. METHODS: Whole-slide images (WSIs) of tissues immunostained with a podocyte nuclear marker and periodic acid-Schiff counterstain were acquired. The data set consisted of murine whole kidney sections (n = 135) from 6 disease models and human kidney biopsy specimens from patients with diabetic nephropathy (DN) (n = 45). Within segmented glomeruli, podocytes were extracted and image analysis was applied to compute measures of podocyte depletion and nuclear morphometry. Computational performance evaluation and statistical testing were performed to validate podometric and associated image features. PodoCount was disbursed as an open-source, cloud-based computational tool. RESULTS: PodoCount produced highly accurate podocyte quantification when benchmarked against existing methods. Podocyte nuclear profiles were identified with 0.98 accuracy and segmented with 0.85 sensitivity and 0.99 specificity. Errors in podocyte count were bounded by 1 podocyte per glomerulus. Podocyte-specific image features were found to be significant predictors of disease state, proteinuria, and clinical outcome. CONCLUSION: PodoCount offers high-performance podocyte quantitation in diverse murine disease models and in human kidney biopsy specimens. Resultant features offer significant correlation with associated metadata and outcome. Our cloud-based tool will provide end users with a standardized approach for automated podometrics from gigapixel-sized WSIs.
引用
- Santo BA, Govind D, Daneshpajouhnejad P, et al. PodoCount: A Robust, Fully Automated, Whole-Slide Podocyte Quantification Tool. Kidney Int Rep. 2022. PMID: 35694561. doi:10.1016/j.ekir.2022.03.004