基于琼脂纸片扩散试验用磺胺酰杂芳基羧酸鉴定产B1亚类金属β-内酰胺酶肠杆菌

Practical Agar-Based Disk Diffusion Tests Using Sulfamoyl Heteroarylcarboxylic Acids for Identification of Subclass B1 Metallo-β-Lactamase-Producing Enterobacterales.
PubMed 文献 · J Clin Microbiol · 2021-07-14

研究开发了三种基于琼脂的纸片扩散试验(双纸片协同试验、纸片增强试验和改良碳青霉烯灭活法),使用B1亚类金属β-内酰胺酶特异性抑制剂SFC和SPC,以区分产B1亚类金属β-内酰胺酶(如IMP、NDM、VIM型)的肠杆菌与其他碳青霉烯酶(尤其是丝氨酸型碳青霉烯酶)。双纸片协同试验和改良碳青霉烯灭活法使用SFC和SPC检测产B1亚类金属β-内酰胺酶肠杆菌的灵敏度为95.3%,特异性为100%;纸片增强试验使用SFC和SPC的灵敏度分别为89.1%和93.8%,特异性均为100%。这些方法简单、廉价且准确率高,有助于临床微生物实验室特异性检测和区分产B1亚类金属β-内酰胺酶肠杆菌。

要点

  • 双纸片协同试验和改良碳青霉烯灭活法使用SFC/SPC检测B1亚类金属β-内酰胺酶肠杆菌灵敏度95.3%、特异性100%。
  • 纸片增强试验使用SFC和SPC的灵敏度分别为89.1%和93.8%,特异性均为100%。
  • 该方法简单、廉价、准确率高,可帮助临床微生物实验室区分B1亚类金属β-内酰胺酶与其他碳青霉烯酶。

核心结论

  • 使用SFC和SPC的琼脂纸片扩散试验可简单、廉价、高准确度地检测和区分产B1亚类金属β-内酰胺酶肠杆菌。

研究设计与样本

  • 研究开发了三种基于琼脂的纸片扩散试验(双纸片协同试验、纸片增强试验和改良碳青霉烯灭活法),使用B1亚类金属β-内酰胺酶特异性抑制剂SFC和SPC。

主要发现

  • 双纸片协同试验和改良碳青霉烯灭活法使用SFC和SPC检测B1亚类金属β-内酰胺酶肠杆菌的灵敏度为95.3%,特异性为100%。
  • 纸片增强试验使用SFC的灵敏度为89.1%,使用SPC的灵敏度为93.8%,两者特异性均为100%。

关键数值与推荐

  • 双纸片协同试验和改良碳青霉烯灭活法使用SFC和SPC:灵敏度95.3%,特异性100%。
  • 纸片增强试验使用SFC:灵敏度89.1%,特异性100%;使用SPC:灵敏度93.8%,特异性100%。

临床怎么用

  • 临床微生物实验室可采用这些简单、廉价的方法特异性检测和区分产B1亚类金属β-内酰胺酶肠杆菌,有助于选择适当治疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The worldwide distribution of carbapenemase-producing Enterobacterales (CPE) is a serious public health concern as they exhibit carbapenem resistance, thus limiting the choice of antimicrobials for treating CPE infections. Combination treatment with a β-lactam and one of the newly approved β-lactamase inhibitors, such as avibactam, relebactam, or vaborbactam, provides a valuable tool to cope with CPE; however, these inhibitors are active only against serine-type carbapenemases and not against metallo-β-lactamases (MβLs). Therefore, it is important to readily differentiate carbapenemases produced by CPE by using simple and reliable methods in order to choose an appropriate treatment. Here, we developed three practical agar-based disk diffusion tests (double-disk synergy test [DDST], disk potentiation test, and modified carbapenem inactivation method [mCIM]) to discriminate the production of subclass B1 MβLs, such as IMP-, NDM-, and VIM-type MβLs, from the other carbapenemases, especially serine-type carbapenemases. This was accomplished using B1 MβL-specific sulfamoyl heteroarylcarboxylic acid inhibitors, 2,5-dimethyl-4-sulfamoylfuran-3-carboxylic acid (SFC) and 2,5-diethyl-1-methyl-4-sulfamoylpyrrole-3-carboxylic acid (SPC), originally developed by us. The DDST and mCIM using SFC and SPC revealed high sensitivity (95.3%) and specificity (100%) in detecting B1 MβL-producing Enterobacterales. In the disk potentiation test, the sensitivities using SFC and SPC were 89.1% and 93.8%, respectively, whereas the specificities for both were 100%. These methods are simple and inexpensive and have a high accuracy rate. These methods would therefore be of immense assistance in the specific detection and discrimination of B1 MβL-producing Enterobacterales in clinical microbiology laboratories and would lead to better prevention against infection with such multidrug-resistant bacteria in clinical settings.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Norizuki C, Wachino JI, Jin W, et al. Practical Agar-Based Disk Diffusion Tests Using Sulfamoyl Heteroarylcarboxylic Acids for Identification of Subclass B1 Metallo-β-Lactamase-Producing Enterobacterales. J Clin Microbiol. 2021. PMID: 34260275. doi:10.1128/JCM.00761-21