基于多表位重组蛋白的间接化学发光免疫分析法检测猪口蹄疫病毒O型抗体
本研究开发了一种基于多表位的间接化学发光免疫分析法(ME-CLIA),用于特异性检测猪血清中口蹄疫病毒(FMDV)O型抗体。该方法具有高诊断敏感性和特异性,与三种商业试剂盒比较了诊断性能、准确率及分析灵敏度,并初步确定了多表位重组疫苗的免疫保护值。用灭活疫苗接种猪评估的ME-CLIA阳性百分比值与液相阻断ELISA(LBPE)滴度呈显著正相关(r=0.8361;P<0.0001),表明ME-CLIA适用于猪FMDV O型抗体检测及多表位和灭活疫苗的效力评价。
要点
- ME-CLIA可特异性检测猪血清中FMDV O型抗体,诊断敏感性和特异性高。
- ME-CLIA与LBPE滴度显著正相关(r=0.8361;P<0.0001)。
- ME-CLIA可作为多表位重组疫苗的匹配检测方法评价免疫保护。
核心结论
- ME-CLIA适用于检测猪FMDV O型抗体及评价多表位和灭活疫苗效力。
研究设计与样本
- 开发基于多表位的间接化学发光免疫分析法(ME-CLIA),并与三种商业试剂盒比较诊断性能、准确率及分析灵敏度。
- 通过免疫攻毒后观察临床症状初步确定多表位重组疫苗的免疫保护值。
- 用灭活疫苗接种猪评估ME-CLIA阳性百分比值与LBPE滴度的相关性。
主要发现
- ME-CLIA呈现高诊断敏感性和 excellent 诊断特异性,可检测广谱FMDV O型抗体。
- ME-CLIA阳性百分比值与LBPE滴度显著正相关(r=0.8361;P<0.0001)。
- ME-CLIA检测的多表位重组疫苗免疫保护值经攻毒后临床症状观察初步确定。
关键数值与推荐
- ME-CLIA与LBPE滴度的相关系数r=0.8361,P<0.0001。
临床怎么用
- ME-CLIA可用于猪FMDV O型抗体血清监测,作为多表位重组疫苗和灭活疫苗的匹配检测方法。
局限性
- 原文未明确报告ME-CLIA与三种商业试剂盒比较的具体数值及样本量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Foot-and-mouth disease virus (FMDV) has led to serious losses in animal husbandry worldwide. Seromonitoring of FMDV postvaccination is important for the control and eradication of foot-and-mouth disease (FMD) in regions and countries where vaccination is widespread. However, many commercial kits present high false-positive rates. In this study, a multiepitope-based indirect chemiluminescence immunoassay (ME-CLIA) was developed for specifically detecting antibodies against FMDV serotype O in swine sera. The developed method presented high diagnostic sensitivity and excellent diagnostic specificity, and it could detect a broad spectrum of antibodies against FMDV serotype O. The diagnostic performance, accuracy rate, and analytical sensitivity of ME-CLIA were compared with those of three commercial kits. The immune protection value of multiple-epitope recombinant vaccine detected using ME-CLIA was preliminarily determined by observation of clinical symptoms postimmunization challenge, the results of which indicated that the ME-CLIA can be employed as a matching detection method for evaluating multiple-epitope recombinant vaccine. The percent positive values of ME-CLIA determined using swine vaccinated with inactivated vaccine were significantly positively correlated with the titers of liquid-phase-blocking enzyme-linked immunosorbent assay (ELISA) (LBPE) (r = 0.8361; P < 0.0001). These results indicated that ME-CLIA is suitable for detection of antibodies against FMDV serotype O in swine and for potency evaluation of multiple-epitope and inactivated vaccines.
引用
- Liu W, Shao J, Zhang G, et al. Development of an Indirect Chemiluminescence Immunoassay Using a Multiepitope Recombinant Protein To Specifically Detect Antibodies against Foot-and-Mouth Disease Virus Serotype O in Swine. J Clin Microbiol. 2021. PMID: 33328177. doi:10.1128/JCM.02464-20
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。