耳念珠菌选择性培养基的研发与验证
本研究开发了一种耳念珠菌选择性培养基(SAM),由含12.5% NaCl和9 mM硫酸亚铁的YPD琼脂组成,42°C培养48小时。95%(127/133)耳念珠菌在48小时内生长,其余6株72小时生长,446株非耳念珠菌完全被抑制;72小时后灵敏度和特异性均为100%。
要点
- SAM培养基含12.5% NaCl和9 mM硫酸亚铁,42°C培养48小时可选择性生长耳念珠菌。
- 验证中95%(127/133)耳念珠菌48小时内生长,非耳念珠菌全部被抑制。
- 72小时培养后灵敏度和特异性均为100%,可作为分子诊断的替代方法。
核心结论
- SAM选择性培养基可用于耳念珠菌的检测和鉴定,成本低且易于配制。
研究设计与样本
- 验证使用579株酵母分离株和40份Bactec血培养信号阳性肉汤。
主要发现
- 95%(127/133)耳念珠菌分离株在48小时内生长于标准化培养基,其余6株在72小时后生长。
- 446株非耳念珠菌酵母分离株的生长被完全抑制。
- 72小时孵育后,测试培养基的灵敏度和特异性均为100%,阳性预测值和阴性预测值也均为100%。
关键数值与推荐
- SAM配方:YPD琼脂含12.5% NaCl和9 mM硫酸亚铁,42°C孵育48小时。
- 72小时孵育后灵敏度和特异性均为100%,阳性预测值和阴性预测值均为100%。
临床怎么用
- 在临床微生物实验室中,SAM可作为分子诊断工具的替代方法,用于耳念珠菌的检测和鉴定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Identification of Candida auris is challenging and requires molecular or protein profiling-based approaches, availability of which is limited in many routine diagnostic laboratories, necessitating the development of a cost-effective, rapid, and reliable method of identification. The objective of this study was to develop a selective medium for C. auris identification. Eighteen C. auris and 30 non-C. auris yeasts were used for the standardization of the selective medium. Sodium chloride (10% to 13% concentration) and ferrous sulfate (8 mM to 15 mM) were added to yeast extract-peptone-dextrose (YPD) agar in various combinations followed by incubation at 37°C, 40°C, or 42°C for 2 to 3 days. For validation, 579 yeast isolates and 40 signal-positive Bactec blood culture (BC) broths were used. YPD agar comprising 12.5% NaCl and 9 mM ferrous sulfate incubated at 42°C for 48 h, named Selective Auris Medium (SAM), allowed selective growth of C. auris A total of 95% (127/133) of C. auris isolates tested grew on the standardized media within 48 h, and the remaining 6 isolates grew after 72 h, whereas the growth of 446 non-C. auris yeast isolates was completely inhibited. The specificity and sensitivity of the test medium were both 100% after 72 h of incubation. The positive and negative predictive values were also noted to be 100% after 72 h of incubation. The formulated selective medium can be used for the detection and identification of C. auris The SAM is inexpensive, can easily be prepared, and can be used as an alternative to molecular diagnostic tools in the clinical microbiology laboratory.
引用
- Das S, Singh S, Tawde Y, et al. A Selective Medium for Isolation and Detection of Candida auris, an Emerging Pathogen. J Clin Microbiol. 2021. PMID: 33208474. doi:10.1128/JCM.00326-20
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。