成人住院患者指尖采血的分析前挑战限制其广泛应用
该前瞻性观察研究对56例接受万古霉素治疗的住院患者的59对静脉与指尖毛细血管血样进行分析,比较万古霉素和基础代谢面板(BMP)结果。除碳酸氢盐和钾外,其余分析物在两种采样方式间具有可比性;但15%病例需多次穿刺,初始30例中因血量不足的拒收率高达30%。作者认为显著的分析前问题应限制指尖采血的广泛采用。
要点
- 除碳酸氢盐和钾外,万古霉素和BMP其他分析物在指尖血与静脉血间可比。
- 15%的病例需穿刺多个手指才能获得足够血量。
- 初始30例中因血量不足的毛细血管样本拒收率高达30%。
核心结论
- 万古霉素和BMP(除钾和碳酸氢盐外)在指尖血与静脉血间分析上可比。
- 显著的分析前问题应阻止实验室和提供者更广泛地采用指尖毛细血管血作为替代采样方法,除非在极端情况下。
研究设计与样本
- 前瞻性观察研究,纳入接受万古霉素治疗的住院患者,采集配对的静脉和指尖毛细血管血样。
- 共分析来自56例独特住院患者的59对指尖和静脉血标本。
- 配对标本在核心实验室的自动化化学和免疫化学平台上检测万古霉素和基础代谢面板(BMP:钙、二氧化碳、氯、钾、钠、肌酐、葡萄糖、血清尿素氮)。
主要发现
- 配对样本在所有检测分析物上可比, except 碳酸氢盐和钾在毛细血管样本组中显著不同。
- 15%的病例需要穿刺多个手指以获得足够血液进行检测。
- 初始30例入组患者中,因血量不足的毛细血管样本拒收率高达30%。
临床怎么用
- 实验室和提供者不应更广泛地采用指尖毛细血管血作为替代采样方法,除非在极端情况下。
- 需注意指尖采血可能导致钾和碳酸氢盐结果显著差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Patient compliance with laboratory testing is one of the most underrecognized challenges in developing a treatment plan for acute and chronically ill patients. The ability to offer alternatives to standard venipuncture blood draws would greatly increase a laboratory's ability to provide testing to patients and health care providers. METHODS: We performed a prospective observational study on paired venous and fingerstick capillary blood samples from admitted patients undergoing vancomycin therapy. Paired specimens were analyzed for vancomycin and a basic metabolic panel (BMP: calcium, carbon dioxide, chloride, potassium, sodium, creatinine, glucose, serum urea nitrogen) on the core laboratory's automated chemistry and immunochemistry platforms. RESULTS: A total of 59 paired fingerstick and venous blood specimens from 56 unique inpatients were analyzed. Paired samples were comparable for all the analytes tested with the exception of bicarbonate and potassium, which were significantly different among the capillary sample group. Patients required multiple fingers be lanced in 15% of cases to obtain sufficient blood to carry out the testing. Capillary sample rejection rates due to insufficient volumes were as high as 30% in the initial 30 patients enrolled in the study. CONCLUSIONS: Vancomycin and the BMP, with the exception of potassium and bicarbonate, were determined to be analytically comparable. However, significant preanalytical issues should preclude laboratories and providers from more widespread adoption of fingerstick-derived capillary blood as an alternative sampling method except in the most extenuating of circumstances.
引用
- Jankowski CA, Casapao AM, Siller S, et al. Preanalytical Challenges During Capillary Fingerstick Sampling Preclude Its Widespread Use in Adult Hospitalized Patients. Am J Clin Pathol. 2021. PMID: 33009571. doi:10.1093/ajcp/aqaa138
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。