文献速递临床免疫分子诊断

十一种SARS-CoV-2抗体快速检测试剂的评估

Evaluation of eleven rapid tests for detection of antibodies against SARS-CoV-2.
PubMed 文献 · Clin Chem Lab Med · 2020-06-29

所有试剂均能检出住院COVID-19患者的抗体但灵敏度各异,在既往感染的康复门诊患者中有5种试剂IgG灵敏度低于65%,在初级急诊疑似患者中灵敏度极低。结论认为快速检测不适合作独立检测现症感染,高IgG灵敏度试剂或可用于确认既往感染。

要点

  • 康复门诊患者中有5种试剂IgG灵敏度低于65%。
  • 初级急诊疑似患者中快速检测灵敏度极低,不宜单独用于现症感染检测。

核心结论

  • 快速检测不适合作独立检测在挪威初级急诊人群中现症感染。
  • 所有快速检测均能检出SARS-CoV-2抗体但灵敏度各异,在病情较重参与者中总体较高。
  • 高IgG灵敏度(及特异度)的快速检测或可用于确认既往感染,引入前应在目标人群独立评估。

研究设计与样本

  • 所有参与者均在临床微生物实验室接受SARS-CoV-2 PCR检测。
  • 第1组为20例PCR确诊COVID-19住院患者。
  • 第2组为23例既往PCR确诊COVID-19的康复门诊患者。
  • 第3组为49例在初级急诊就诊的疑似COVID-19参与者。

主要发现

  • 康复门诊患者中试剂间IgG灵敏度存在差异,5种试剂灵敏度低于65%。
  • 初级急诊疑似COVID-19参与者中快速检测灵敏度极低。
  • 大多数快速检测易于操作和判读。

临床怎么用

  • 快速检测不宜单独用于初级急诊人群现症感染的检测。
  • 高IgG灵敏度(及特异度)的快速检测或可用于确认既往感染。
  • 引入快速检测前应在目标人群进行独立评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: SARS-CoV-2, causing COVID-19, has emerged to cause a human pandemic. Detection of SARS-CoV-2 in respiratory samples by using PCR is the standard laboratory diagnostic tool. Our aim was to perform a limited evaluation of the diagnostic performance and user-friendliness of eleven rapid tests for detection of antibodies against SARS-CoV-2. METHODS: All participants were tested with PCR against SARS-CoV-2 at a clinical microbiology laboratory. Comparing with results from PCR tests, we evaluated the rapid tests' performances in three arms; 1) 20 hospitalized patients with PCR-confirmed COVID-19, 2) 23 recovered outpatients with former PCR-confirmed COVID-19, and 3) 49 participants with suspected COVID-19 presenting at a primary care emergency room. RESULTS: All eleven tests detected antibodies in hospitalized COVID-19 patients, though with varying sensitivities. In former outpatients recovered from COVID-19, there were differences between tests in the immunoglobulin type G (IgG) sensitivity, with five tests having a sensitivity below 65%. In participants with suspected COVID-19 infection, the rapid tests had very low sensitivities. Most rapid tests were easy to perform and interpret. CONCLUSIONS: Rapid tests were not suited as stand-alone tests to detect present infection in a Norwegian primary care emergency room population. All the rapid tests were able to detect SARS-CoV-2 antibodies, although sensitivities varied and were generally higher in the study arm of more severely affected participants. Rapid tests with high IgG sensitivity (and specificity) may be useful for confirmation of past infection. An independent evaluation should be performed in the intended population before introducing a rapid test.

来源:Clin Chem Lab Med,查看原文。版权归原作者所有。

引用

  1. Tollånes MC, Bakken Kran AM, Abildsnes E, et al. Evaluation of eleven rapid tests for detection of antibodies against SARS-CoV-2. Clin Chem Lab Med. 2020. PMID: 32598303. doi:10.1515/cclm-2020-0628

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。