FecalSwab用于粪便标本储存及BD Max系统分子检测肠道病原体的评估
该研究评估FecalSwab作为BD Max系统病毒和细菌肠道面板的标本类型,用186份未保存粪便标本制备匹配的粪便和FecalSwab样本。加载50μl FecalSwab标本时,所有靶标性能与粪便等效(P > 0.48);4°C储存14天分子检测灵敏度保持,但未冷藏时肠道细菌检测可变。
要点
- FecalSwab加载50μl时,BD Max所有靶标检测性能与匹配粪便等效(P > 0.48)
- 4°C储存14天,多数病毒靶标(除星状病毒)检测不受影响(ΔCT ≤ 1)
- 未冷藏(22°C或35°C)时肠道细菌检测结果可变
核心结论
- FecalSwab与匹配粪便在BD Max系统上检测肠道病原体性能等效,4°C储存可维持分子检测灵敏度,适合作为标本类型。
研究设计与样本
- 研究收集186份未保存粪便标本,制备匹配的粪便和FecalSwab样本,在BD Max系统上使用病毒和细菌肠道面板检测。
主要发现
- 加载50μl FecalSwab标本时,所有靶标检测性能与粪便等效(P > 0.48)。
- 4°C、22°C或35°C储存14天内,多数病毒靶标(除星状病毒)检测不受影响(ΔCT ≤ 1)。
- 未冷藏(22°C或35°C)时,肠道细菌检测结果可变。
关键数值与推荐
- FecalSwab标本加载体积为50μl时,BD Max检测性能与粪便等效(P > 0.48)。
- 4°C储存14天,多数病毒靶标ΔCT ≤ 1。
临床怎么用
- FecalSwab可作为BD Max系统肠道病原体分子检测的标本类型,推荐4°C储存和运输以维持检测灵敏度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The FecalSwab system (Copan Italia, Brescia, Italy) is a convenient alternative to bulk stool for the diagnosis of enteric pathogens. Although the U.S. Food and Drug Administration (FDA) approved for transport and culture of enteric bacterial pathogens, the FecalSwab has not been well assessed for its suitability with molecular platforms. In this study, we evaluated the FecalSwab as a specimen type for the BD Max system using the viral and bacterial enteric panels (BD Diagnostics, Baltimore, MD, USA). A total of 186 unpreserved stool specimens were collected and used to prepare matched bulk stool and FecalSwab samples. Performance was equivalent (P > 0.48) to bulk stool for all targets when 50 μl of FecalSwab specimen was loaded onto the BD Max assays. As stool specimens are often collected off-site from the clinical microbiology laboratory and require transport, we assessed the stability of stool specimens stored for up to 14 days at 4°C, 22°C, or 35°C to account for varying transportation conditions. Molecular detection for the majority of viral targets (excluding astrovirus) was unaffected (change in cycle threshold [ΔCT ] ≤ 1) by sample storage temperature over the 2-week period; however, detection of enteric bacteria was variable if specimens were not refrigerated (22°C or 35°C). By demonstrating equivalent performance to matched bulk stool and maintaining molecular detection sensitivity when stored at 4°C, we suggest that the FecalSwab is a suitable specimen type for enteropathogen diagnostics on the BD Max system.
引用
- Richard-Greenblatt M, Rutherford C, Luinstra K, et al. Evaluation of the FecalSwab for Stool Specimen Storage and Molecular Detection of Enteropathogens on the BD Max System. J Clin Microbiol. 2020. PMID: 32461284. doi:10.1128/JCM.00178-20
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。