文献速递分子诊断质量管理与危急值

热灭活对低病毒载量SARS-CoV-2核酸检测假阴性的影响

Potential False-Negative Nucleic Acid Testing Results for Severe Acute Respiratory Syndrome Coronavirus 2 from Thermal Inactivation of Samples with Low Viral Loads.
PubMed 文献 · Clin Chem · 2020-01-01

该研究探讨56°C热灭活对SARS-CoV-2逆转录PCR(RT-PCR)检测的影响,发现热灭活后弱阳性样本的Ct值升高,约半数弱阳性样本(7/15,46.7%)在至少一次平行检测中转为阴性;而胍盐裂解保存的假阴性率较低(2/15,13.3%)。结论提示热灭活可能降低RT-PCR检测效率,需考虑其他保障实验室人员安全的方案。

要点

  • 56°C热灭活可导致低病毒载量样本RT-PCR假阴性。
  • 弱阳性样本热灭活后约半数在至少一次检测中转为阴性。
  • 胍盐裂解保存对RT-PCR影响较小,假阴性率更低。

核心结论

  • 热灭活对SARS-CoV-2的RT-PCR检测效率有不利影响,可能导致低病毒载量样本假阴性。

研究设计与样本

  • 研究探讨热灭活对SARS-CoV-2定量RT-PCR结果的影响,特别是低病毒载量样本的假阴性率,并比较不同样本类型、保存时间和化学灭活方法的效果。

主要发现

  • 热灭活后,确诊COVID-19患者样本的RT-PCR Ct值升高。
  • 弱阳性样本中,7/15(46.7%)在热灭活后至少一次平行检测中RT-PCR阴性。
  • 胍盐裂解保存的样本假阴性较少(2/15,13.3%),且Ct值升高幅度显著低于热灭活。

关键数值与推荐

  • 热灭活条件为56°C。
  • 弱阳性样本热灭活后假阴性率为46.7%(7/15)。
  • 胍盐裂解保存的假阴性率为13.3%(2/15)。

临床怎么用

  • 对于低病毒载量样本,应谨慎使用56°C热灭活,考虑采用胍盐裂解等化学灭活方法以减少假阴性。
  • 需权衡实验室人员安全与检测准确性,探索其他保护措施。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Coronavirus disease-2019 (COVID-19) has spread widely throughout the world since the end of 2019. Nucleic acid testing (NAT) has played an important role in patient diagnosis and management of COVID-19. In some circumstances, thermal inactivation at 56°C has been recommended to inactivate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) before NAT. However, this procedure could theoretically disrupt nucleic acid integrity of this single-stranded RNA virus and cause false negatives in real-time polymerase chain reaction (RT-PCR) tests. METHODS: We investigated whether thermal inactivation could affect the results of viral NAT. We examined the effects of thermal inactivation on the quantitative RT-PCR results of SARS-CoV-2, particularly with regard to the rates of false-negative results for specimens carrying low viral loads. We additionally investigated the effects of different specimen types, sample preservation times, and a chemical inactivation approach on NAT. RESULTS: Our study showed increased Ct values in specimens from diagnosed COVID-19 patients in RT-PCR tests after thermal incubation. Moreover, about half of the weak-positive samples (7 of 15 samples, 46.7%) were RT-PCR negative after heat inactivation in at least one parallel testing. The use of guanidinium-based lysis for preservation of these specimens had a smaller impact on RT-PCR results with fewer false negatives (2 of 15 samples, 13.3%) and significantly less increase in Ct values than heat inactivation. CONCLUSION: Thermal inactivation adversely affected the efficiency of RT-PCR for SARS-CoV-2 detection. Given the limited applicability associated with chemical inactivators, other approaches to ensure the overall protection of laboratory personnel need consideration.

来源:Clin Chem,查看原文。版权归原作者所有。

引用

  1. Pan Y, Long L, Zhang D, et al. Potential False-Negative Nucleic Acid Testing Results for Severe Acute Respiratory Syndrome Coronavirus 2 from Thermal Inactivation of Samples with Low Viral Loads. Clin Chem. 2020. PMID: 32246822. doi:10.1093/clinchem/hvaa091

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。