文献速递临床微生物分子诊断

新型多重PCR panel与定量细菌培养诊断下呼吸道感染的比较评估

Evaluation of a Novel Multiplex PCR Panel Compared to Quantitative Bacterial Culture for Diagnosis of Lower Respiratory Tract Infections.
PubMed 文献 · J Clin Microbiol · 2020-04-23

该研究回顾性比较Unyvero下呼吸道panel与常规定量细菌培养在175份残余BALF中的表现,可分析129份阳性样本的181个靶标及46份阴性样本,微生物靶标PPA为96.5%、NPA为99.6%,可分析耐药靶标与表型药敏一致率为79%(14/18)。

要点

  • Unyvero LRT panel可在5小时内多重快速检测20种肺炎病原体及耐药基因。
  • 微生物靶标与定量培养的阳性符合率为96.5%,阴性符合率为99.6%。
  • 可分析耐药靶标与表型药敏一致率为79%(14/18)。

核心结论

  • Unyvero LRT panel与常规定量细菌培养结果总体高度一致。

研究设计与样本

  • 回顾性研究,在175份残余BALF上比较分子panel与常规定量细菌培养方法。

主要发现

  • 可分析129份阳性样本的181个靶标及46份阴性样本,微生物靶标PPA为96.5%、NPA为99.6%。
  • PPA低于100%的靶标为金黄色葡萄球菌34/37(91.9%)、肺炎链球菌10/11(90.9%)和阴沟肠杆菌复合群2/4(50%)。
  • 可分析耐药靶标与表型药敏试验一致率为79%(14/18)。

关键数值与推荐

  • Unyvero LRT panel可在采集后5小时内多重快速检测20种肺炎潜在病原体并检测耐药基因序列。

临床怎么用

  • 该panel与定量培养高度一致,但原文未报告结局或临床影响研究,临床使用需结合此局限。

局限性

  • 本研究为回顾性研究,未进行结局或临床影响研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Quantitative bacterial culture of bronchoalveolar lavage fluids (BALF) is labor-intensive, and the delay involved in performing culture, definitive identification, and susceptibility testing often results in prolonged use of broad-spectrum antibiotics. The Unyvero lower respiratory tract (LRT) panel (Curetis, Holzgerlingen, Germany) allows the multiplexed rapid detection and identification of 20 potential etiologic agents of pneumonia within 5 h of collection. In addition, the assay includes detection of gene sequences that confer antimicrobial resistance. We retrospectively compared the performance of the molecular panel to routine quantitative bacterial culture methods on remnant BALF. Upon testing 175 BALF, we were able to analyze positive agreement of 181 targets from 129 samples, and 46 samples were negative. The positive percent agreement (PPA) among the microbial targets was 96.5%, and the negative percent agreement (NPA) was 99.6%. The targets with a PPA of <100% were Staphylococcus aureus (34/37 [91.9%]), Streptococcus pneumoniae (10/11 [90.9%]), and Enterobacter cloacae complex (2/4 [50%]). For the analyzable resistance targets, concordance with phenotypic susceptibility testing was 79% (14/18). This study found the Unyvero LRT panel largely concordant with culture results; however, no outcome or clinical impact studies were performed.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Collins ME, Popowitch EB, Miller MB, et al. Evaluation of a Novel Multiplex PCR Panel Compared to Quantitative Bacterial Culture for Diagnosis of Lower Respiratory Tract Infections. J Clin Microbiol. 2020. PMID: 32075901. doi:10.1128/JCM.02013-19

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。