文献速递临床微生物分子诊断

商业试验检测产志贺毒素大肠埃希菌的诊断准确性:系统综述与荟萃分析

Diagnostic Test Accuracy of Commercial Tests for Detection of Shiga Toxin-Producing Escherichia coli: A Systematic Review and Meta-Analysis.
PubMed 文献 · Clin Chem · 2020-01-01

EIA合并敏感性0.681(95%CI 0.571-0.773),特异性1.00(95%CI 0.998-1.00);PCR合并敏感性1.00(95%CI 0.904-1.00),特异性0.999(95%CI 0.997-0.999)。PCR敏感性高于EIA且特异性无明显损失,但证据确定性低。

要点

  • PCR检测STEC的合并敏感性为1.00,显著高于EIA的0.681。
  • PCR与EIA的特异性均接近1.00,差异无临床意义。
  • 证据确定性低至极低,结果可能高估性能差异。

核心结论

  • PCR检测STEC比EIA更敏感,且特异性无明显损失。
  • 但由于证据确定性低,结果可能高估性能差异。

研究设计与样本

  • 系统综述与荟萃分析,检索已发表和灰色文献。
  • 参照标准包括至少一种核酸扩增试验。
  • 采用QUADAS-2评估质量,双变量随机效应模型进行荟萃分析。
  • 使用GRADE方法评估证据确定性。

主要发现

  • EIA合并敏感性0.681(95%CI 0.571-0.773;证据确定性极低)。
  • EIA合并特异性1.00(95%CI 0.998-1.00;证据确定性中等)。
  • PCR合并敏感性1.00(95%CI 0.904-1.00;证据确定性低)。
  • PCR合并特异性0.999(95%CI 0.997-0.999;证据确定性低)。
  • 证据确定性因高偏倚风险而降级。

临床怎么用

  • PCR检测STEC敏感性更高,可考虑优先用于快速检测。
  • EIA特异性高但敏感性较低,阴性结果需谨慎解读。

局限性

  • 证据确定性低至极低,结果可能高估性能差异。
  • 纳入研究存在高偏倚风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rapid detection of Shiga toxin-producing Escherichia coli (STEC) enables appropriate monitoring and treatment. We synthesized available evidence to compare the performance of enzyme immunoassay (EIA) and PCR tests for the detection of STEC. METHODS: We searched published and gray literature for studies of STEC EIA and/or PCR diagnostic test accuracy relative to reference standards including at least one nucleic acid amplification test. Two reviewers independently screened studies, extracted data, and assessed quality with the second version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Bivariate random effects models were used to meta-analyze the clinical sensitivity and specificity of commercial EIA and PCR STEC diagnostic tests, and summary receiver operator characteristic curves were constructed. We evaluated the certainty of evidence with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. RESULTS: We identified 43 articles reflecting 25 260 specimens. Meta-analysis of EIA and PCR accuracy included 25 and 22 articles, respectively. STEC EIA pooled sensitivity and specificity were 0.681 (95% CI, 0.571-0.773; very low certainty of evidence) and 1.00 (95% CI, 0.998-1.00; moderate certainty of evidence), respectively. STEC PCR pooled sensitivity and specificity were 1.00 (95% CI, 0.904-1.00; low certainty of evidence) and 0.999 (95% CI, 0.997-0.999; low certainty of evidence), respectively. Certainty of evidence was downgraded because of high risk of bias. CONCLUSIONS: PCR tests to identify the presence of STEC are more sensitive than EIA tests, with no meaningful loss of specificity. However, given the low certainty of evidence, our results may overestimate the difference in performance.

来源:Clin Chem,查看原文。版权归原作者所有。

引用

  1. Tarr GAM, Lin CY, Vandermeer B, et al. Diagnostic Test Accuracy of Commercial Tests for Detection of Shiga Toxin-Producing Escherichia coli: A Systematic Review and Meta-Analysis. Clin Chem. 2020. PMID: 32040589. doi:10.1093/clinchem/hvz006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。