文献速递临床血液与体液质量管理与危急值

健康中国人群13项血液学参数的长期生物学变异估计

Long-term biological variation estimates of 13 hematological parameters in healthy Chinese subjects.
PubMed 文献 · Clin Chem Lab Med · 2020-01-01

该研究对41名健康中国受试者(22女19男,23-59岁)连续6个月每月采血一次,用ABX Pentra 80仪器双份检测13项全血细胞计数参数,按BIVAC清单计算性别分层的个体内和个体间生物学变异。除白细胞、中性粒细胞和淋巴细胞外,10项参数均值存在显著性别差异,需分区个体间变异;多数变异估计与近期欧洲人群数据无显著差异。

要点

  • 多数血液学参数生物学变异与欧洲人群估计相似。
  • 除白细胞、中性粒细胞、淋巴细胞外,10项参数均值有性别差异。
  • 男女个体内变异估计无显著差异。

核心结论

  • 符合BIVAC的研究中多数生物学变异估计相似。
  • 血液细胞更新时间和参与者年龄分布应在全血细胞计数生物学变异研究中考虑。

研究设计与样本

  • 41名健康中国受试者(22女19男,23-59岁),连续6个月每月采血一次,ABX Pentra 80仪器双份检测13项全血细胞计数参数,按BIVAC清单进行嵌套方差分析。

主要发现

  • 去除离群值后每名受试者剩余数据为442-484个。
  • 男女个体内变异估计无显著差异。
  • 除白细胞、中性粒细胞和淋巴细胞外,10项参数均值存在显著性别差异,需分区个体间变异数据。
  • 多数生物学变异估计与近期发表的欧洲人群估计无显著差异。

关键数值与推荐

  • 每名受试者剩余数据442-484个。
  • 13项全血细胞计数参数。
  • 41名健康中国受试者(22女19男,23-59岁)。

临床怎么用

  • 为中国人群全血细胞计数参数的分析性能规范提供生物学变异数据。
  • 提示性别分区个体间变异适用于除白细胞、中性粒细胞和淋巴细胞外的10项参数。

局限性

  • 样本量较小(41名)。
  • 仅使用单一ABX Pentra 80仪器。
  • 研究周期为6个月。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background The complete blood count (CBC) is a basic test routinely ordered by physicians as a part of initial diagnostic work-up on their patients. To ensure safe clinical application of the CBC, reliable biological variation (BV) data are needed to establish analytical performance specifications. Our aim was to define the BV of CBC parameters using a rigorous protocol that is compliant with the Biological Variation Data Critical Appraisal Checklist (BIVAC) provided by the European Federation of Clinical Chemistry and Laboratory Medicine. Methods Blood samples drawn from 41 healthy Chinese subjects (22 females and 19 males; 23-59 years of age) once monthly for 6 consecutive months were analyzed using an ABX Pentra 80 instrument. The instrument was precisely calibrated. All samples were analyzed in duplicate for 13 CBC parameters. The data were assessed for outliers, normality, and variance homogeneity prior to nested ANOVA. Gender-stratified within-subject (CVI) and between-subject (CVG) BV estimates were calculated. Results The number of remaining data for each subject was 442-484 after removing outliers. No significant differences existed between female/male CVI estimates. Except for leukocytes, neutrophils, and lymphocytes, the mean values of 10 parameters differed significantly between genders, rendering partitioning of CVG data between genders. No significant differences were detected between most BV estimates and recently published estimates representing a Europid population. Conclusions Most BV estimates in BIVAC-compliant studies are similar. The turnover time of blood cells and age distribution of participants should be considered in a CBC BV study. Our study will contribute to global BV estimates and future studies.

来源:Clin Chem Lab Med,查看原文。版权归原作者所有。

引用

  1. Li C, Peng M, Wu J, et al. Long-term biological variation estimates of 13 hematological parameters in healthy Chinese subjects. Clin Chem Lab Med. 2020. PMID: 32069228. doi:10.1515/cclm-2019-1141

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。