抗链霉亲和素抗体在免疫分析中的干扰:罕见现象还是更常见发现?
该研究检测了两例ASA干扰患者的多份样本及500份随机样本的抗链霉亲和素IgG和IgM浓度,并对100份样本在Cobas分析仪上比较中和前后TSH比值与ASA浓度的关系。结果显示AS-IgM浓度与TSH比值正相关,500份中8份超过AS-IgM cut-off值,两例患者滴度显著突出,提示ASA干扰比既往认为的更常见且由IgM抗体引起。
要点
- ASA干扰比既往认为的更常见,且由IgM抗体引起。
- AS-IgM浓度与TSH中和前后比值呈正相关。
- 500份随机样本中8份超过AS-IgM cut-off值。
核心结论
- ASA干扰比最初认为的更普遍,且由IgM抗体引起。
研究设计与样本
- 检测两例ASA干扰患者多份样本及500份随机样本的AS-IgG和AS-IgM浓度。
- 对100份样本子集在Cobas分析仪上比较中和前后TSH,并分析TSH比值与ASA浓度的关系。
- 用SDS-PAGE和免疫印迹分析S. avidinii菌落提取物。
主要发现
- AS-IgM浓度与TSH中和后/中和前比值呈正相关。
- 500份样本中8份超过计算的AS-IgM cut-off值。
- 两例患者AS-IgM滴度在人群中显著突出。
- 普通人群存在AS-IgM反应性连续谱,两例患者代表该谱末端。
- 病例与对照的免疫印迹模式未见差异,可能提示ASA在人群中普遍存在。
关键数值与推荐
- 500份随机样本中8份超过计算的AS-IgM cut-off值。
- 100份样本子集用于TSH中和前后比值与ASA浓度关系分析。
临床怎么用
- 对疑似免疫分析干扰样本可考虑检测AS-IgM并采用中和方案去除ASA后复测。
局限性
- 原文未报告具体cut-off数值、TSH比值范围、P值及免疫印迹细节。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background Anti-streptavidin antibodies (ASA) may cause analytical interference on certain immunoassay platforms. Streptavidin is purified from the non-pathogenic Streptomyces avidinii soil bacterium. In contrast to interference with biotin, ASA interference is supposed to be much rarer. In-depth studies on this topic are lacking. Therefore, we carried out an analysis toward the prevalence and the possible underlying cause of this interference. Methods Anti-streptavidin (AS)-immunoglobulin G (IgG) and AS-IgM concentrations were determined on multiple samples from two patients with ASA interference and on 500 random samples. On a subset of 100 samples, thyroid-stimulating hormone (TSH) was measured on a Cobas analyzer before and after performing a neutralization protocol which removes ASA. The relationship between the ratio of TSH after neutralization/TSH before neutralization and the ASA concentration was evaluated. Subsequently, an extract of S. avidinii colonies was analyzed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and immunoblotting. Results A positive correlation between AS-IgM concentrations and TSH ratio was obtained. Eight samples out of 500 exceeded the calculated AS-IgM cut-off value. In comparison to the AS-IgM concentrations in the population, titers from the two described cases clearly stood out. The isolated cases represent the end of a broader spectrum as there is a continuum of AS-IgM reactivity in the general population. We could not observe any differences in the immunoblot patterns between the cases and controls, which may indicate the general presence of ASA in the population. Conclusions Interference due to ASA is more prevalent than initially thought and is caused by IgM antibodies.
引用
- Verougstraete N, Berth M, Vaneechoutte M, et al. Interference of anti-streptavidin antibodies in immunoassays: a very rare phenomenon or a more common finding? Clin Chem Lab Med. 2020. PMID: 31782946. doi:10.1515/cclm-2019-1064
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。