淋病奈瑟菌阿奇霉素药敏试验方法间变异比较
该研究比较了琼脂稀释法、MIC试纸条和Etest三种方法检测淋病奈瑟菌对阿奇霉素药敏结果的变异。共测试107株临床分离株和9株参考株,发现Etest与琼脂稀释法一致性更高,MIC试纸条几何平均MIC最高且与琼脂稀释法一致性低,不同方法导致CLSI/EUCAST分类差异,可能影响耐药监测报告。
要点
- Etest与琼脂稀释法一致性为91%,优于MIC试纸条的44%。
- MIC试纸条几何平均MIC为0.8 mg/L,显著高于Etest和琼脂稀释法。
- 按CLSI/EUCAST,琼脂稀释法、MIC试纸条和Etest分别将96%、85%和95%临床株判为敏感/野生型。
核心结论
- 淋病奈瑟菌阿奇霉素药敏试验结果因方法不同而异,可能影响实验室间耐药监测报告。
研究设计与样本
- 用琼脂稀释法和两种MIC梯度条(MIC试纸条和Etest)平行检测107株临床分离株和9株参考株,Etest和MIC试纸条做双份重复。
主要发现
- 双份重复试验1个log2内一致率:MIC试纸条87%,Etest 100%(P < 0.001)。
- 与琼脂稀释法基本一致率:Etest 91%,MIC试纸条44%(P < 0.001)。
- 几何平均MIC:MIC试纸条0.8 mg/L,显著高于Etest 0.47 mg/L(P < 0.001)和琼脂稀释法0.26 mg/L(P < 0.001)。
- Etest MIC值高于琼脂稀释法(P < 0.001)。
- 按CLSI/EUCAST标准,琼脂稀释法、MIC试纸条和Etest分别将96%、85%和95%的临床分离株判为敏感/野生型(P = 0.003)。
关键数值与推荐
- 双份重复1个log2内一致率:MIC试纸条87%,Etest 100%(P < 0.001)。
- 与琼脂稀释法基本一致率:Etest 91%,MIC试纸条44%(P < 0.001)。
- 几何平均MIC:MIC试纸条0.8 mg/L,Etest 0.47 mg/L,琼脂稀释法0.26 mg/L。
- CLSI/EUCAST敏感/野生型分类比例:琼脂稀释法96%,MIC试纸条85%,Etest 95%(P = 0.003)。
临床怎么用
- 实验室应知晓阿奇霉素药敏结果依赖方法,报告时需注明所用方法。
- 监测项目中方法差异可能影响耐药率比较,应统一方法或谨慎解读。
局限性
- 仅评估阿奇霉素对淋病奈瑟菌的药敏,未涉及其他药物。
- 临床分离株和参考株数量有限,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Azithromycin is a component of empirical treatment regimens for Neisseria gonorrhoeae infections, but antimicrobial susceptibility testing for this agent is technically challenging. We compared the intertest variability, MIC values, and CLSI/EUCAST categorization of clinical and reference isolates of N. gonorrhoeae treated with azithromycin by testing 107 clinical isolates and nine reference isolates by agar dilution and in duplicates using MIC test strips (Liofilchem, Italy) and Etests (bioMérieux, France). Replicate isolate agreement within 1 log2 between duplicate tests was 87% for MIC test strips and 100% for Etests (P < 0.001). Essential agreement with the agar dilution method was higher for Etests (91%) than for MIC test strips (44%, P < 0.001). The geometric mean MIC was highest for MIC test strips (0.8 mg/liter) and significantly higher than both Etest (0.47 mg/liter, P < 0.001) and agar dilution (0.26 mg/liter, P < 0.001) methods. Etest MICs were higher than those obtained with agar dilution (P < 0.001). Agar dilution, MIC test strip, and Etest methods categorized 96%, 85%, and 95% (P = 0.003) of clinical isolates, respectively, as susceptible/wild type according to CLSI/EUCAST criteria. Our results illustrate the difficulties underlying azithromycin susceptibility testing for N. gonorrhoeae and demonstrate that results can vary using different methods. This variability could influence antimicrobial resistance reporting between laboratories involved in N. gonorrhoeae surveillance programs.
引用
- McAuliffe GN, Smith M, Cooper G, et al. Variability in Azithromycin Susceptibility Results for Neisseria gonorrhoeae Obtained Using Gradient MIC Strip and Agar Dilution Techniques. J Clin Microbiol. 2019. PMID: 31578264. doi:10.1128/JCM.01353-19
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。