四种方法直接从血培养中检测产碳青霉烯酶肠杆菌科细菌的系统比较
本研究开发了从阳性血培养中快速检测碳青霉烯酶产生的方案,在浓度和溶血步骤后评估四种方法(β-Carba、bcCarba NP、NeoRapid Carb 和 bcCIM)。用 185 株分子特征明确的肠杆菌科分离株(81 株碳青霉烯酶阴性,104 株 CPE)模拟血培养,结果显示 bcCIM 灵敏度和特异度均为 100%,β-Carba 为 100%/95.1%,bcCarba NP 为 99.0%/95.1%,NeoRapid Carb 为 99.0%/91.4%。
要点
- bcCIM 对 CPE 检测灵敏度和特异度均为 100%。
- β-Carba 灵敏度 100%、特异度 95.1%,结果时间 20–45 分钟。
- bcCarba NP 和 NeoRapid Carb 灵敏度均为 99.0%。
核心结论
- 所有评估方法均表现出良好的 CPE 检测能力,方案易于在临床微生物实验室实施,可能有助于早期优化 CPE 血流感染的治疗。
研究设计与样本
- 在阳性血培养经浓度和溶血步骤后,评估四种方法(β-Carba、bcCarba NP、NeoRapid Carb 和 bcCIM)对 185 株分子特征明确的肠杆菌科分离株模拟血培养的检测性能。
主要发现
- 灵敏度/特异度:bcCarba NP 为 99.0%/95.1%,NeoRapid Carb 为 99.0%/91.4%,β-Carba 为 100%/95.1%,bcCIM 为 100%/100%。
- 挑战集合包括 81 株碳青霉烯酶阴性分离株和 104 株 CPE(OXA-48 n=25、NDM n=20、KPC n=18、VIM n=25、GIM n=5、OXA-48-like n=9、OXA-48-like 加 NDM n=2)。
- 弱水解碳青霉烯酶(如 OXA-48-like)也被各检测方法良好检出。
- 结果时间:β-Carba 为 20 至 45 分钟,bcCarba NP 为 2 至 3 小时,NeoRapid Carb 为 2.5 至 2 小时,bcCIM 为 18 至 24 小时。
关键数值与推荐
- bcCarba NP 灵敏度/特异度 99.0%/95.1%。
- NeoRapid Carb 灵敏度/特异度 99.0%/91.4%。
- β-Carba 灵敏度/特异度 100%/95.1%。
- bcCIM 灵敏度/特异度 100%/100%。
临床怎么用
- 这些方案可容易地在临床微生物实验室实施,可能有助于早期优化 CPE 血流感染的治疗。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Early identification of infections caused by carbapenemase-producing Enterobacterales (CPE) can help to optimize patient treatment and improve outcome. In this study, protocols for rapid detection of carbapenemase production directly from positive blood cultures were developed applying a concentration and hemolysis step before a test for carbapenemase production was performed. Four different methods (three modified colorimetric assays [β-Carba, bcCarba NP, and NeoRapid Carb] and a variation of the carbapenem inactivation method [CIM] test with blood cultures [bcCIM]) were assessed on blood cultures spiked with 185 different molecularly characterized Enterobacterales isolates. The challenge collection included 81 carbapenemase-negative isolates and 104 CPEs (OXA-48 [n = 25], NDM [n = 20], KPC [n = 18], VIM [n = 25], GIM [n = 5], OXA-48-like [n = 9], and OXA-48-like plus NDM [n = 2]). The sensitivity/specificity was 99.0%/95.1% for bcCarba NP, 99.0%/91.4% for NeoRapid Carb, 100%/95.1% for β-Carba and 100%/100% for bcCIM. Weakly hydrolyzing carbapenemases (e.g., OXA-48-like) were also well detected by the assays. The time to result was 20 to 45 min for β-Carba, 2 to 3 h for bcCarba NP, 2.5 to 2 h for NeoRapid Carb, and 18 to 24 h for bcCIM. In conclusion, all assays demonstrated good detection of CPE. The protocols can be easily implemented in any clinical microbiology laboratory and could help to optimize therapy early in bloodstream infections by CPE.
引用
- Meier M, Hamprecht A. Systematic Comparison of Four Methods for Detection of Carbapenemase-Producing Enterobacterales Directly from Blood Cultures. J Clin Microbiol. 2019. PMID: 31413083. doi:10.1128/JCM.00709-19
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。