文献速递临床微生物质量管理与危急值

调整改良碳青霉烯酶灭活法条件以快速检测产碳青霉烯酶鲍曼不动杆菌

Adjustment of Modified Carbapenem Inactivation Method Conditions for Rapid Detection of Carbapenemase-Producing Acinetobacter baumannii.
PubMed 文献 · Ann Lab Med · 2020-01-01

该研究评估了改良碳青霉烯酶灭活法(mCIM)和CIMTris中基质对美罗培南(MEM)纸片稳定性的影响,并调整mCIM条件以提高检测产碳青霉烯酶鲍曼不动杆菌的灵敏度和特异性。结果显示,TSB营养肉汤比Tris-HCl pH 7.6更适合作为mCIM基质,优化后mCIM的灵敏度和特异性均为100%。

要点

  • TSB营养肉汤是mCIM检测鲍曼不动杆菌碳青霉烯酶的适宜基质。
  • Tris-HCl pH 7.6会导致MEM纸片活性丢失,不适用于CIMTris。
  • 优化后mCIM检测产碳青霉烯酶鲍曼不动杆菌的灵敏度和特异性均为100%。

核心结论

  • 建立了简单、准确且可重复的优化mCIM条件,用于检测产碳青霉烯酶鲍曼不动杆菌。

研究设计与样本

  • 评估了TSB和Tris-HCl基质对美罗培南纸片稳定性的影响,并调整mCIM条件以提高筛选灵敏度和特异性。

主要发现

  • 基质在孵育2小时或4小时后对MEM纸片稳定性有影响。
  • 与Tris-HCl pH 7.6相比,TSB营养肉汤是mCIM的适宜基质,而Tris-HCl pH 7.6导致CIMTris中MEM活性丢失。
  • 优化后mCIM的灵敏度和特异性均为100%。

关键数值与推荐

  • 优化后mCIM检测产碳青霉烯酶鲍曼不动杆菌的灵敏度为100%,特异性为100%。

临床怎么用

  • 临床实验室可采用TSB营养肉汤作为mCIM基质,并应用优化条件快速检测产碳青霉烯酶鲍曼不动杆菌。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The existing modified carbapenem inactivation methods (mCIMs) recommended by the CLSI for detecting carbapenemase production have not been applicable for Acinetobacter baumannii. We evaluated the influence of matrices used in mCIMs and CIMTris on the stability of the disks for detecting carbapenemase producers and suggested optimal mCIM conditions for detecting carbapenemase-producing A. baumannii. METHODS: Seventy-three A. baumannii isolates characterized for antimicrobial susceptibility and carbapenemase encoding genes were tested for carbapenemase production using mCIM and CIMTris. The influence of the matrices (Tryptic soy broth [TSB] and Tris-HCl) used in these methods on the stability of the meropenem (MEM) disk was also evaluated. The mCIM conditions were adjusted to enhance screening sensitivity and specificity for detecting carbapenemase-producing A. baumannii. RESULTS: The matrices had an impact on the stability of the MEM disk after the incubation period (two or four hrs). TSB nutrient broth is an appropriate matrix for mCIM compared with Tris-HCl pH 7.6, which leads to the loss of MEM activity in CIMTris. The sensitivity and the specificity of the optimal mCIM were both 100%. CONCLUSIONS: We established optimal mCIM conditions for simple, accurate, and reproducible detection of carbapenemase-producing A. baumannii.

来源:Ann Lab Med,查看原文。版权归原作者所有。

引用

  1. Vu TN, Byun JH, D'Souza R, et al. Adjustment of Modified Carbapenem Inactivation Method Conditions for Rapid Detection of Carbapenemase-Producing Acinetobacter baumannii. Ann Lab Med. 2020. PMID: 31432635. doi:10.3343/alm.2020.40.1.21

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。