CALIPER健康儿童队列中17项Roche cobas 8000 e602免疫分析项目的儿科参考区间
研究基于CALIPER健康儿童队列,纳入741名1天至<19岁的健康儿童和青少年,在Roche cobas 8000 e602免疫分析仪上检测17项内分泌和特殊化学标志物,按年龄和性别建立参考区间及90%置信区间。所有分析物均需年龄分区,其中8项需性别分区。这是首个针对Roche免疫分析项目建立的儿科参考区间,与CALIPER其他平台结果相似。
要点
- 所有17项分析物均需年龄分区,尤其生命早期和青春期。
- 8项分析物需性别分区,包括铁蛋白、TSH、TT3及除泌乳素外的性激素。
- 该参考区间与CALIPER其他平台结果相似,有助于结果解读。
核心结论
- 首次建立了17项Roche免疫分析项目的儿科参考区间,与CALIPER其他分析平台结果总体相似。
研究设计与样本
- 研究纳入741名1天至<19岁的健康儿童和青少年,在Roche cobas 8000 e602免疫分析仪上检测17项免疫分析项目。
- 按年龄和性别建立参考区间,并依据CLSI指南计算相应的90%置信区间。
主要发现
- 所有分析物的参考值均需要年龄分区,尤其在生命早期和整个青春期。
- 17项分析物中有8项需要性别分区,包括铁蛋白、促甲状腺激素(TSH)、总三碘甲状腺原氨酸(TT3)以及除泌乳素外的所有生育/性激素。
临床怎么用
- 建立的参考区间可提高使用Roche免疫分析仪的临床实验室对检验结果解读的准确性,并改善临床决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background The diagnostic utility of laboratory tests in paediatric medicine relies heavily on the availability of appropriate reference intervals (RIs). The Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) has established a comprehensive database of covariate-stratified RIs for many paediatric laboratory tests using a large, healthy reference population. Several automated analysers in widespread use in clinical laboratories have already been studied. Here, we extend the testing to Roche immunoassays and report, for the first time, comprehensive paediatric RIs for 17 endocrine and special chemistry markers. Methods A total of 741 healthy children and adolescents (1 day to <19 years) were recruited and serum samples were analysed for 17 immunoassays on the Roche cobas 8000 e602 Immunoassay Analyzer. Age and sex-specific RIs were established and corresponding 90% confidence intervals (CIs) were calculated in accordance with Clinical and Laboratory Standards Institute guidelines. Results Reference values for all analytes measured required age partitioning, particularly during early life and throughout adolescence. Of the 17 analytes measured, eight required sex partitioning, including ferritin, thyroid stimulating hormone (TSH), total triiodothyronine (TT3) and all fertility/sex hormones, except prolactin. Conclusions This is the first study to determine accurate paediatric RIs for Roche immunoassays. RIs were generally similar to those previously published by CALIPER on other analytical platforms, highlighting the reproducibility of age- and sex-specific trends in reference values observed across the paediatric age range. The RIs established in this study will improve the accuracy of test result interpretation and clinical decision-making in clinical laboratories utilising Roche immunoassays.
引用
- Bohn MK, Higgins V, Asgari S, et al. Paediatric reference intervals for 17 Roche cobas 8000 e602 immunoassays in the CALIPER cohort of healthy children and adolescents. Clin Chem Lab Med. 2019. PMID: 31377737. doi:10.1515/cclm-2019-0707
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。