文献速递临床微生物临床血液与体液

含抗生素结合树脂需氧血培养瓶在β-内酰胺类和氟喹诺酮类暴露后对革兰阴性菌的回收

Recovery of Gram-Negative Bacteria from Aerobic Blood Culture Bottles Containing Antibiotic Binding Resins after Exposure to β-Lactam and Fluoroquinolone Concentrations.
PubMed 文献 · J Clin Microbiol · 2019-09-24

本研究评估美罗培南、亚胺培南、头孢吡肟、头孢唑林、左氧氟沙星和哌拉西林-他唑巴坦在临床意义的峰、中、谷浓度下,对含树脂的BacT/Alert FA Plus与Bactec Aerobic/F血培养瓶回收铜绿假单胞菌、大肠埃希菌和肺炎克雷伯菌的影响。结果显示含抗生素时病原体回收明显降低,尤其在高浓度下,支持在给予抗生素前立即采血培养。

要点

  • 含树脂血培养瓶在抗生素存在下病原体回收明显降低,峰浓度时最低
  • 铜绿假单胞菌回收率随抗生素浓度降低而升高(峰20%、中80%、谷100%,P≤0.001)
  • 支持在抗生素给药前立即采集血培养以提高病原体检出机会

核心结论

  • 含抗生素结合树脂的BacT/Alert FA Plus和Bactec Aerobic/F血培养瓶在抗生素存在下病原体回收大幅降低,尤其在较高浓度时。

研究设计与样本

  • 体外研究:评估美罗培南、亚胺培南、头孢吡肟、头孢唑林、左氧氟沙星和哌拉西林-他唑巴坦在临床意义的峰、中、谷浓度下,对含树脂BacT/Alert FA Plus与Bactec Aerobic/F血培养瓶回收铜绿假单胞菌、大肠埃希菌和肺炎克雷伯菌的影响。

主要发现

  • 接种铜绿假单胞菌的瓶在抗假单胞菌药峰、中、谷浓度下阳性报警分别为4/20(20%)、16/20(80%)、20/20(100%)(P≤0.001)。
  • 大肠埃希菌在峰、中、谷浓度下回收分别为8/24(33%)、11/24(46%)、14/24(58%)(P=0.221)。
  • 肺炎克雷伯菌在所有研究抗生素浓度下回收均为8/16(50%)(P=1.0)。
  • 接种铜绿假单胞菌时BacT/Alert与Bactec瓶的检出时间(TTD)相似(P=0.352)。
  • 含抗生素的BacT/Alert瓶对大肠埃希菌(P=0.026)和肺炎克雷伯菌(P≤0.001)的TTD短于含抗生素的Bactec瓶。

临床怎么用

  • 支持在给予抗生素剂量前立即采集血培养,以最大化病原体回收机会。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Blood culture bottles containing antibiotic binding resins are routinely used to minimize artificial sterilization in the presence of antibiotics. However, the resin binding kinetics can differ between antibiotics and concentrations. This study assessed the impact of clinically meaningful peak, midpoint, and trough concentrations of meropenem, imipenem, cefepime, cefazolin, levofloxacin, and piperacillin-tazobactam on the recovery of Pseudomonas aeruginosa, Escherichia coli, and Klebsiella pneumoniae from resin-containing BacT/Alert FA Plus and Bactec Aerobic/F blood culture bottles. P. aeruginosa-inoculated bottles alarmed positive in 4/20 (20%), 16/20 (80%), and 20/20 (100%) of those with peak, midpoint, and trough concentrations of antipseudomonal agents, respectively (P ≤ 0.001). E. coli was recovered from 8/24 (33%), 11/24 (46%), and 14/24 (58%) of bottles with peak, midpoint, and trough concentrations, respectively (P = 0.221). K. pneumoniae was recovered from 8/16 (50%) at all concentrations of the studied antibiotics (P = 1.0). BacT/Alert and Bactec bottles inoculated with antibiotics and P. aeruginosa had similar times to detection (TTD) (P = 0.352); however, antibiotic-containing BacT/Alert bottles had a shorter TTD compared with antibiotic-containing Bactec bottles for E. coli (P = 0.026) and K. pneumoniae (P ≤ 0.001). Pathogen recovery in BacT/Alert FA Plus and Bactec Aerobic/F blood culture bottles containing antibiotic binding resins was greatly reduced in the presence of antibiotics, especially at higher concentrations. These data support the practice of drawing blood cultures immediately before an antibiotic dose to maximize the chances of pathogen recovery.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Chen IH, Nicolau DP, Kuti JL, et al. Recovery of Gram-Negative Bacteria from Aerobic Blood Culture Bottles Containing Antibiotic Binding Resins after Exposure to β-Lactam and Fluoroquinolone Concentrations. J Clin Microbiol. 2019. PMID: 31340990. doi:10.1128/JCM.00849-19