该研究在三级护理微生物实验室评估两种工作流程优化对A组链球菌(GAS)核酸扩增检测(NAAT)实验室内周转时间(TAT)的影响。线性回归显示,直接标本提交至微生物实验室、自动审核及夜班处理可显著缩短实验室内TAT。
要点
- 直接气动管道提交标本至微生物实验室可缩短GAS NAAT实验室内TAT。
- 实验室信息系统自动审核GAS NAAT结果可缩短实验室内TAT。
- 夜班处理也是缩短实验室内TAT的独立因素。
核心结论
- 直接标本提交至微生物实验室和自动审核两种工作流程优化可缩短GAS NAAT的实验室内周转时间。
研究设计与样本
- 本研究为回顾性实验室记录分析,在三级护理微生物实验室实施Xpert Xpress Strep A检测(GeneXpert Infinity-48s)后开展。
主要发现
- 线性回归显示,直接标本提交至微生物实验室、自动审核及夜班处理均与实验室内总TAT显著缩短相关。
临床怎么用
- 微生物实验室在规划NAAT实施早期阶段可考虑仪器接口和标本处理流程优化。
- 全实验室自动化和按需NAAT的应用有助于实现更精简的微生物标本处理流程。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The use of some nucleic acid amplification tests (NAATs) for the diagnosis of group A Streptococcus (GAS) pharyngitis allows laboratories to adopt single-tiered testing without reflex culture. However, centralization may delay the delivery of actionable information to the bedside, particularly in the outpatient setting. We describe two novel workflows at our institution and their effect on in-lab turnaround time (TAT) at a tertiary care microbiology lab. Laboratory records were extracted, and relevant data were analyzed after the implementation of qualitative in vitro diagnostic testing for GAS with the Xpert Xpress Strep A assay, performed using the GeneXpert Infinity-48s. Workflow optimization steps studied included: (i) direct specimen submission to the microbiology laboratory via the pneumatic tube system and (ii) autoverification of GAS NAAT results in the laboratory information system. Between April 2018 and October 2018, 2,595 unique specimens were tested for GAS by PCR. Of these, 2,523 were included in the final analysis. Linear regression established that the total in-lab TAT was significantly reduced by direct specimen submission to the microbiology laboratory, autoverification, and processing during the night shift. We describe two workflow optimization methods that reduced the in-lab TAT for GAS NAAT. Although microbiology labs historically use manual processes, the advent of total laboratory automation and the adoption of on-demand NAATs will allow for more streamlined processing of microbiology specimens. It may be beneficial to consider instrument interfacing and specimen processing optimization during the early phases of implementation planning for NAATs in the microbiology laboratory.
引用
- Durant TJS, Merwede J, Reynolds J, et al. Optimization of Turnaround Time for Group A Streptococcus PCR. J Clin Microbiol. 2019. PMID: 31217271. doi:10.1128/JCM.00619-19
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。