多重实时PCR-shortTUB法检测涂阴低菌载量样本中的结核分枝杆菌复合群

Multiplex Real-Time PCR-shortTUB Assay for Detection of the Mycobacterium tuberculosis Complex in Smear-Negative Clinical Samples with Low Mycobacterial Loads.
PubMed 文献 · J Clin Microbiol · 2019-07-26

该研究评估多重实时PCR-shortTUB法检测结核分枝杆菌复合群(MTBC)的性能,与常规培养法比较。该法靶向whiB3和pstS1两基因,对94例涂阴低菌载量肺外及肺部样本检测,总体敏感性88%、特异性95%。该技术有望用于常规临床微生物检测以缩短MTBC检测周转时间。

要点

  • 多重实时PCR-shortTUB法靶向whiB3和pstS1两基因,LOD分别为10拷贝和100拷贝。
  • 94例涂阴低菌载量样本中总体敏感性88%、特异性95%。
  • 胸水敏感性83%,组织/活检标本敏感性85%。

核心结论

  • 多重实时PCR-shortTUB法可用于检测涂阴低菌载量临床样本中的MTBC,有望缩短检测周转时间并辅助肺外结核诊断。

研究设计与样本

  • 研究评估多重实时PCR-shortTUB法与常规培养法比较检测MTBC的性能。
  • 共分析94例肺外及肺部样本,均为涂阴,其中75例MTBC培养阳性。

主要发现

  • 该法靶向whiB3和pstS1两基因,LOD分别为10拷贝和100拷贝,扩增效率分别为92%和99.7%。
  • 总体敏感性88%,特异性95%。
  • 胸水敏感性83%,组织/活检标本敏感性85%。

关键数值与推荐

  • whiB3基因LOD为10拷贝,pstS1基因LOD为100拷贝。
  • whiB3扩增效率92%,pstS1扩增效率99.7%。
  • 总体敏感性88%,特异性95%;胸水敏感性83%,组织/活检敏感性85%。

临床怎么用

  • 该技术可纳入常规临床微生物检测,用于缩短MTBC检测周转时间。
  • 可用于肺外结核诊断及低菌载量肺部样本的检测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Tuberculosis (TB) remains a major health problem worldwide. Control of TB requires rapid, accurate diagnosis of active disease. However, extrapulmonary TB is very difficult to diagnose because the clinical specimens have very low bacterial loads. Several molecular methods involving direct detection of the Mycobacterium tuberculosis complex (MTBC) have emerged in recent years. Real-time PCR amplification simultaneously combines the amplification and detection of candidate sequences by using fluorescent probes (mainly TaqMan or Molecular Beacons) in automated systems. The multiplex real-time PCR-short assay is performed using locked nucleic acid (LNA) probes (length, 8 to 9 nucleotides) in combination with CodUNG to detect multiple pathogens in clinical samples. In this study, we evaluated the performance of this novel multiplex assay for detecting the MTBC in comparison with that of the conventional culture-based method. The multiplex real-time PCR-shortTUB assay targets two genes, whiB3 (redox-responsive transcriptional regulator) and pstS1 (phosphate-specific transporter), yielding limits of detection (LOD) of 10 copies and 100 copies, respectively, and amplification efficiencies of 92% and 99.7%, respectively. A total of 94 extrapulmonary samples and pulmonary samples with low mycobacterial loads (all smear negative; 75 MTBC culture positive) were analyzed using the test, yielding an overall sensitivity of 88% and a specificity of 95%. For pleural fluid and tissues/biopsy specimens, the sensitivity was 83% and 85%, respectively. In summary, this technique could be implemented in routine clinical microbiology testing to reduce the overall turnaround time for MTBC detection and may therefore be a useful tool for the diagnosis of extrapulmonary tuberculosis and diagnosis using pulmonary samples with low mycobacterial loads.

来源:J Clin Microbiol,查看原文。版权归原作者所有。