MCR-1肠杆菌侧流免疫层析法的开发与多中心验证
研究开发了基于单克隆抗体的侧流免疫层析法(LFIA),用于快速检测产MCR-1肠杆菌。多中心测试177株人源和121株动物源肠杆菌分离株,结果显示该方法检测MCR-1的灵敏度为100%、特异度为98%,可快速、简便、经济地用于微生物实验室。
要点
- LFIA检测产MCR-1肠杆菌灵敏度100%、特异度98%。
- 单菌落悬液加样后15分钟判读,阳性呈粉红色条带。
- 不检测MCR-3、MCR-4、MCR-5,MCR-2部分交叉。
核心结论
- LFIA可快速、灵敏、特异地检测产MCR-1肠杆菌,适用于全球微生物实验室。
研究设计与样本
- 采用精选单克隆抗体制备LFIA,多中心测试177株人源和121株动物源肠杆菌分离株。
主要发现
- 所有产MCR-1分离株LFIA均为阳性,未见假阴性。
- 4株产MCR-2分离株中3株LFIA阳性。
- LFIA不检测产MCR-3、MCR-4或MCR-5的分离株。
- LFIA检测MCR-1灵敏度100%、特异度98%。
关键数值与推荐
- 挑取琼脂平板上的单个菌落悬于提取缓冲液,加样至卡盒,迁移15分钟,观察特异性条带。
- 阳性结果呈现粉红色线条,判读明确。
临床怎么用
- 可用于人源和动物源样本中产MCR-1肠杆菌的快速检测和监测。
局限性
- 不能检测MCR-3、MCR-4、MCR-5,对MCR-2存在部分交叉反应。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Colistin has become a last-resort antibiotic for the treatment of infections caused by highly drug-resistant Gram-negative bacteria. Moreover, it has been widely used in the livestock sector. As a consequence, colistin resistance is emerging worldwide. Among the colistin resistance mechanisms, the spread of the plasmid-encoded colistin resistance gene mcr-1 (mostly in Escherichia coli) is of particular concern due to its increased transferability compared to that of chromosome-encoded resistance. The early detection of MCR-1-producing bacteria is essential to prevent further spread and provide appropriate antimicrobial therapy. Lateral flow immunoassays (LFIAs) were manufactured with selected monoclonal antibodies. A collection of 177 human and 121 animal enterobacterial isolates was tested in a multicentric study. One bacterial colony grown on agar plates was suspended in extraction buffer and dispensed on the cassette. Migration was allowed for 15 min, and the results were monitored by the appearance of a specific band. The positive results showed a pink line resulting in an unambiguous interpretation. All MCR-1-producing isolates were found to be positive by the LFIA, and no false-negative results were observed. Three out of four MCR-2-producing isolates were also found to be positive. Our test does not detect MCR-3-, MCR-4-, or MCR-5-producing isolates. LFIA allows the detection of MCR-1 with 100% sensitivity and 98% specificity. This test is fast, sensitive, specific, easy to use, and cost-effective and can therefore be implemented in any microbiology laboratory worldwide. LFIA is a major tool for the rapid detection and monitoring of MCR-1 producers in humans and animals.
引用
- Volland H, Dortet L, Bernabeu S, et al. Development and Multicentric Validation of a Lateral Flow Immunoassay for Rapid Detection of MCR-1-Producing Enterobacteriaceae. J Clin Microbiol. 2019. PMID: 30842227. doi:10.1128/JCM.01454-18
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。