文献速递临床血液与体液质量管理与危急值

全血INR即时检测试纸条连续批次的准确性评估:冷冻血浆池的作用澄清

Accuracy assessment of consecutive test strip lots for whole blood INR point-of-care instruments: clarifying the role of frozen plasma pools.
PubMed 文献 · Clin Chem Lab Med · 2019-01-01

该研究评估了CoaguChek XS试纸条连续批次的INR准确性及冷冻血浆池用于准确性评价的适用性。冷冻血浆池与全血关系线距离超出互换性临界值,不适用于评估绝对准确性。

要点

  • 全血INR在1.5-4.5时,所有评估试纸条批次均满足±10%分析偏倚标准。
  • 试纸条批次间INR差异与批次序号呈正趋势(p<0.001)。
  • 冷冻血浆池与全血关系线距离超出互换性临界值,不适用于绝对准确性评估。

核心结论

  • 使用全血样本时,所有评估的CoaguChek XS试纸条批次均满足±10%分析偏倚标准。
  • 冷冻血浆池与全血行为不同,不适用于评估新试纸条的绝对准确性。

研究设计与样本

  • 荷兰合作中心每年以特定批次的CoaguChek XS试纸条为参考批,参考批已用国际标准凝血活酶rTF/09验证,建立参考批INR与国际标准INR的关系R1。
  • 新批次与参考批通过患者毛细血管全血样本比较,建立新批INR与参考批INR的关系R2;血样本INR在1.5-4.5区间。
  • 平行分析三个冷冻血浆池,评估每个血浆点与关系线R2的距离。

主要发现

  • 试纸条批次与国际标准rTF/09的平均INR差异在-0.14至+0.20之间(-4%至+8%)。
  • 观察到与试纸条批次序号的正趋势(p<0.001)。
  • 在若干情况下,冷冻血浆与全血关系线R2的距离大于互换性临界值。

关键数值与推荐

  • 全血样本INR范围:1.5-4.5。
  • 分析偏倚标准:±10%。
  • 平均INR差异范围:-0.14至+0.20(-4%至+8%)。
  • 趋势检验P值:p<0.001。

临床怎么用

  • 使用全血样本验证新试纸条批次时,所有批次均满足±10%偏倚标准。
  • 不应使用冷冻血浆池评估CoaguChek XS试纸条的绝对准确性。

局限性

  • 冷冻血浆池与全血关系线距离超出互换性临界值,不适用于绝对准确性评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background In the Netherlands, each new lot of test strips for the CoaguChek XS is validated by a group of collaborating centers. The purpose of this study was to assess the accuracy of the international normalized ratio (INR) measured with consecutive test strip lots and the suitability of frozen plasma pools for accuracy evaluation. Methods Each year, a particular lot of CoaguChek XS test strips is used as reference lot. The reference lots have been validated with the International Standard for thromboplastin rTF/09, yielding a mathematical relationship (R1) between reference lot INR and International Standard INR. New lots are compared to the reference lot using patients' capillary blood samples, yielding a relationship (R2) between the new lot INR and the reference lot INR. INRs of the blood samples were within the 1.5-4.5 interval. In parallel, three frozen plasmas pools are analyzed with the test strips. The distance of each plasma point to the line of relationship R2 was assessed. Results Fifty-four test strip lots have been evaluated during 3 years (2014-2016). Mean INR differences between test strip lot and International Standard rTF/09 varied between -0.14 and +0.20 (-4% and +8%, respectively). A positive trend with strip lot sequence number was observed (p<0.001). In several cases, the distance of the frozen plasmas to the whole blood relationship (R2) was greater than the critical value for commutability. Conclusions Using whole blood, all evaluated test strip lots met the analytical bias criterion of ±10%. Frozen plasma pools behave differently compared to whole blood and are not suitable for assessing absolute accuracy of new CoaguChek XS test strips.

来源:Clin Chem Lab Med,查看原文。版权归原作者所有。

引用

  1. van den Besselaar AMHP, Abdoel CF, van Rijn CJJ, et al. Accuracy assessment of consecutive test strip lots for whole blood INR point-of-care instruments: clarifying the role of frozen plasma pools. Clin Chem Lab Med. 2019. PMID: 30763258. doi:10.1515/cclm-2018-1054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。