人绒毛膜促性腺激素疑似异嗜性抗体干扰的免疫测定调查:推荐方法
共发现5例HAb及类HAb干扰,Beckman测定干扰频率为6.7%,Roche测定为2.9%;异嗜性阻断剂未能检出40%的干扰病例。结论认为不应单独使用阻断剂,需结合系列稀释和替代平台等多种策略。
要点
- hCG免疫测定中HAb干扰可导致假性升高,需在结果与临床不符时进行调查。
- Beckman和Roche测定系统均观察到HAb干扰,频率分别为6.7%和2.9%。
- 异嗜性阻断剂漏检40%干扰病例,应联合系列稀释和替代平台排查。
核心结论
- 在Beckman和Roche hCG免疫测定中均观察到HAb干扰,异嗜性阻断剂未能检出40%的干扰病例。
主要发现
- 共发现5例HAb及类HAb干扰,Beckman测定的干扰频率为6.7%,Roche测定为2.9%。
- 3例通过异嗜性阻断剂和替代方法检出HAb,另2例通过替代方法结果不一致及非线性系列稀释检出(类HAb)。
关键数值与推荐
- HAb干扰调查包括使用两种免疫测定在异嗜性阻断剂处理样本前后进行测量,并进行系列稀释研究。
- 异嗜性阻断剂未能检出40%的干扰病例。
临床怎么用
- 当hCG免疫测定结果与临床发现不一致时,应进行HAb干扰调查。
- 不应单独使用阻断剂进行HAb干扰调查,应结合系列稀释和使用替代平台等多种策略。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background Heterophile antibody (HAb) interferences in immunoassays can cause falsely elevated hCG concentrations leading to incorrect diagnosis and treatments options. When results are not consistent with the clinical findings, hCG HAb interference investigation may be requested by the physician. A retrospective evaluation of the frequency of HAb interference was performed among cases of physician-requested investigations and the effectiveness of commercially available blocking reagents to detect HAb interference in two immunoassay systems was evaluated. Methods One hundred and thirteen physician requests for hCG HAb investigation from 2008 to 2017 were reviewed. The primary method used to measure hCG was the Beckman Coulter Access Total βhCG (2008-2010) and the Roche Elecsys HCG+β (2014-2017). HAb investigation included measurement by two immunoassays before and after treatment of samples with heterophile blocking reagents and serial dilution studies. Results Five cases of HAb and HAb-like interference were identified. The interference frequency was 6.7% for the Beckman assay and 2.9% for the Roche assay. The presence of HAb was detected using heterophile blocking reagents and an alternative method in three cases. The other two cases were detected due to discrepant results with an alternative method and non-linear serial dilutions (HAb-like). Conclusions HAb interference was observed in the Beckman and the Roche assays. The heterophile blocking reagents failed to detect 40% of interference cases. Blocking reagents should not solely be used for these investigations. Multiple strategies including the use of serial dilutions and using an alternative platform are critical when troubleshooting interferences in hCG immunoassays.
引用
- Jara-Aguirre JC, Baumann NA, Block DR, et al. Human chorionic gonadotropin suspected heterophile interference investigations in immunoassays: a recommended approach. Clin Chem Lab Med. 2019. PMID: 30753153. doi:10.1515/cclm-2018-1142
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。