韩国新生儿干血斑LC-MS/MS多类固醇谱分析
该研究开发并验证了一种液相色谱-串联质谱(LC-MS/MS)方法,可同时定量干血斑(DBS)中九种类固醇激素,并在1146例韩国新生儿(272例早产儿和874例足月儿)中建立了参考区间。与免疫分析法相比,LC-MS/MS检测17α-羟孕酮存在负偏倚(免疫法测值更高,r=0.8104,P<0.0001),并成功应用于14例额外样本的先天性肾上腺皮质增生症(CAH)筛查与诊断。
要点
- 建立了DBS中九种类固醇的LC-MS/MS定量方法并验证了性能。
- 提供了韩国早产儿和足月儿九种类固醇的参考区间。
- 免疫法测17α-羟孕酮较LC-MS/MS偏高,提示假阳性风险。
核心结论
- LC-MS/MS方法可高灵敏、高特异地从DBS中评估九种类固醇,是CAH临床分析的有前景工具。
研究设计与样本
- 研究开发并验证了LC-MS/MS方法,评估线性、精密度、准确性、提取回收率和基质效应,并在1146例DBS样本(272例早产儿和874例足月儿)中确定参考区间。
- 对17α-羟孕酮比较了免疫分析法与LC-MS/MS法,并用14例额外样本验证临床适用性。
主要发现
- 线性范围:皮质醇2.8-828.0 nmol/L,其他类固醇0.9-40.0 nmol/L(R²>0.99)。
- 日内和日间精密度CV分别为2.52-12.26%和3.53-17.12%。
- 准确性为80.81-99.94%,提取回收率为88.0-125.4%,基质效应为61.7-74.2%。
- 免疫法测值较LC-MS/MS存在负偏倚(免疫法更高,r=0.8104,P<0.0001)。
- LC-MS/MS方法成功应用于14例额外样本的九种类固醇分析,用于CAH筛查和诊断。
关键数值与推荐
- 皮质醇线性范围2.8-828.0 nmol/L,其他类固醇0.9-40.0 nmol/L(R²>0.99)。
- 日内精密度CV 2.52-12.26%,日间精密度CV 3.53-17.12%。
- 准确性80.81-99.94%,提取回收率88.0-125.4%,基质效应61.7-74.2%。
- 免疫法与LC-MS/MS测17α-羟孕酮相关性r=0.8104,P<0.0001。
临床怎么用
- LC-MS/MS法可用于新生儿DBS中九种类固醇的同时定量,辅助CAH筛查与诊断。
- 免疫法测17α-羟孕酮存在高偏倚,LC-MS/MS可减少假阳性。
- 参考区间基于韩国早产儿和足月儿DBS样本建立,临床解读时需考虑人群和胎龄。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Screening for congenital adrenal hyperplasia (CAH) using immunoassays for 17α-hydroxyprogesterone generates many false-positive results. We developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for simultaneous quantification of nine steroid hormones in dried blood spot (DBS) samples, and established reference intervals for these hormones. METHODS: We examined our method for linearity, precision, accuracy, extraction recovery, and matrix effects and determined the reference intervals of cortisol, 17α-hydroxyproges-terone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, 11-deoxycorticosterone, testosterone, and progesterone in 1,146 DBS samples (from 272 preterm and 874 full-term neonates). Immunoassay and LC-MS/MS methods were compared for 17α-hydroxyprogesterone. Fourteen additional samples were tested to validate the clinical applicability of the LC-MS/MS method. RESULTS: The linearity range was 2.8-828.0 nmol/L for cortisol and 0.9-40.0 nmol/L for the other steroids (R²>0.99). Intra-day and inter-day precision CVs were 2.52-12.26% and 3.53-17.12%, respectively. Accuracy was 80.81-99.94%, and extraction recovery and matrix effects were 88.0-125.4% and 61.7-74.2%, respectively. There was a negative bias, with higher values measured by immunoassay compared with LC-MS/MS (r=0.8104, P<0.0001). The LC-MS/MS method was successfully applied to the analysis of nine steroids in DBS for screening and diagnosis of CAH using the 14 additional samples. CONCLUSIONS: Our method enables highly sensitive and specific assessment of nine steroids from DBS and is a promising tool for clinical analysis of CAH.
引用
- Choi R, Park HD, Oh HJ, et al. Dried Blood Spot Multiplexed Steroid Profiling Using Liquid Chromatography Tandem Mass Spectrometry in Korean Neonates. Ann Lab Med. 2019. PMID: 30623618. doi:10.3343/alm.2019.39.3.263
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。