光引发化学发光法快速定量临床样本中过敏原特异性IgG4
本研究基于光引发化学发光法(LICA)开发了一种快速、灵敏的同质免疫分析法,用于定量血清中过敏原特异性IgG4(sIgG4)。通过优化生物素化过敏原浓度、稀释范围和孵育时间,该方法定量下限为0.261 ng/mL,变异系数小于10%,且不受生理浓度干扰物影响。临床样本检测显示,鸡蛋过敏组Gal d 1、Gal d 2和Gal d 3-sIgG4水平显著升高(p < .05),而Gal d 4-sIgG4组间无差异。
要点
- LICA法可快速定量过敏原sIgG4,定量下限0.261 ng/mL,CV<10%。
- 鸡蛋过敏组Gal d 1、d 2、d 3-sIgG4显著升高,Gal d 4无差异。
- 该方法性能良好,可用于临床过敏原sIgG4检测。
核心结论
- LICA法性能满意,可用于临床定量过敏原sIgG4。
研究设计与样本
- 方法学研究:基于光引发化学发光法(LICA)建立同质免疫分析,检测血清过敏原sIgG4。
- 通过多组实验优化工作条件并评估性能,并比较鸡蛋过敏组与对照组的sIgG4水平。
主要发现
- 最佳生物素化过敏原浓度为250 ng/mL。
- 最佳稀释范围:Gal d 1、Gal d 2 sIgG4为1:8,Gal d 3、Gal d 4 sIgG4为1:4。
- 最佳孵育时间:Gal d 1、Gal d 2 sIgG4为20 min,Gal d 3、Gal d 4 sIgG4为40 min。
- 定量下限(LLOQ)为0.261 ng/mL,变异系数(CV)<10%。
- 鸡蛋过敏组Gal d 1、Gal d 2和Gal d 3-sIgG4水平显著高于对照组(p < .05),Gal d 4-sIgG4组间无差异。
关键数值与推荐
- 生物素化过敏原最佳浓度250 ng/mL。
- Gal d 1、Gal d 2 sIgG4最佳稀释比例1:8;Gal d 3、Gal d 4 sIgG4最佳稀释比例1:4。
- Gal d 1、Gal d 2 sIgG4最佳孵育时间20 min;Gal d 3、Gal d 4 sIgG4最佳孵育时间40 min。
- LLOQ为0.261 ng/mL;CV<10%。
- 鸡蛋过敏组Gal d 1、Gal d 2、Gal d 3-sIgG4显著升高(p < .05),Gal d 4-sIgG4无显著差异。
临床怎么用
- 可用于临床血清过敏原sIgG4的快速定量检测。
- 检测不同过敏原sIgG4时需按项目采用相应的稀释比例和孵育时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: An increase in allergen-specific IgG4 (sIgG4), which serves as a blocking antibody, is associated with acquisition of immune tolerance after immunotherapy. In this study, we developed a rapid, sensitive, and homogeneous immunoassay based on the light-initiated chemiluminescent assay (LICA) technology for quantifying allergen sIgG4 in serum samples. METHODS: Allergen sIgG4 was measured in vitro by incubating the sample with biotinylated allergens and chemiluminescent beads coated with anti-human IgG4 antibody, followed by the addition of streptavidin-coated sensitizer beads. Multiple tests were performed to optimize the working conditions of the LICA and evaluate its performance. RESULTS: We established the optimal concentration of biotinylated allergens (250 ng/mL), the optimal dilution range (1:8 for Gal d 1, Gal d 2 sIgG4 and 1:4 for Gal d 3, Gal d 4 sIgG4), and the optimal incubation time (20 min for Gal d 1, Gal d 2 sIgG4 and 40 min for Gal d 3, Gal d 4 sIgG4). The lower limit of quantification (LLOQ) was 0.261 ng/mL. The coefficient variation (CV) of the LICA was <10%. The assay was unaffected by general interfering substances at physiological concentrations. It exhibited excellent accuracy to detect allergen-sIgG4 in human serum. Additionally, we demonstrated that the levels of Gal d 1, Gal d 2, and Gal d 3-sIgG4 were significantly higher in the egg allergy group (p < .05), but no differences were found between the groups for Gal d 4-sIgG4. CONCLUSIONS: The LICA demonstrated satisfactory performance and can be used for quantifying allergen sIgG4 in clinical practice.
引用
- Li J, Li S, Huang L, et al. A light-initiated chemiluminescent assay for rapid quantitation of allergen-specific IgG4 in clinical samples. Clin Chim Acta. 2018. PMID: 30517849. doi:10.1016/j.cca.2018.11.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。