六种样本即答式甲/乙型流感及呼吸道合胞病毒核酸检测平台在儿童呼吸道标本中的比较
研究以225份儿童鼻咽拭子对比六种样本即答式核酸扩增平台检测甲型流感病毒(FluA)、乙型流感病毒(FluB)和呼吸道合胞病毒(RSV),以CDC实时逆转录PCR为参照。所有平台检测FluA灵敏度均>95%;仅Fusion、Xpert和Liat三个平台检测FluB和RSV灵敏度均>95%。
要点
- 六种平台检测FluA灵敏度均>95%。
- 仅Fusion、Xpert、Liat检测FluB和RSV灵敏度均>95%。
- Simplexa检测FluB灵敏度85.4%,相对较低。
核心结论
- 六种样本即答式平台检测FluA均表现高灵敏度,但检测FluB和RSV时仅Fusion、Xpert和Liat灵敏度均超过95%。
研究设计与样本
- 用225份儿童鼻咽拭子标本比较六种样本即答式核酸扩增平台,以CDC实时逆转录PCR为参照,并对不一致结果做亚型分析。
主要发现
- FluA灵敏度/特异度:Fusion 100/100、Xpert 98.6/99.3、Liat 100/100、Aries 98.6/100、Simplexa 98.6/100、RP 100/100。
- FluB灵敏度/特异度:Fusion 100/100、Xpert 97.9/99.4、Liat 97.9/98.3、Aries 93.7/99.4、Simplexa 85.4/99.4、RP 95.8/97.7。
- RSV灵敏度/特异度:Xpert 98.1/99.4、Liat 98.1/99.4、Fusion 96.3/100、Aries 94.4/100、Simplexa 87/94.4、RP 94.4/100。
- 确认的75株FluA包括29株pH1N1、39株H3N2、4株sH1N1和3株未分型。
- 确认的48株FluB包括33株Yamagata系、13株Victoria系、1株Yamagata与Victoria双系和1株未知系。
关键数值与推荐
- 六种平台检测FluA灵敏度均>95%。
- Fusion、Xpert和Liat三个平台检测FluB和RSV灵敏度均>95%。
临床怎么用
- 在儿童呼吸道标本检测中,可优先选择对FluA、FluB和RSV灵敏度均较高的Fusion、Xpert或Liat平台。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The rapid and accurate detection of influenza A virus (FluA), influenza B virus (FluB), and respiratory syncytial virus (RSV) improves patient care. Sample-to-answer (STA) platforms based on nucleic acid amplification and detection of these viruses are simple, automated, and accurate. We compared six such platforms for the detection of FluA, FluB, and RSV: Cepheid GeneXpert Xpress Flu/RSV (Xpert), Hologic Panther Fusion Flu A/B/RSV (Fusion), Cobas influenza A/B & RSV (Liat), Luminex Aries Flu A/B & RSV (Aries), BioFire FilmArray respiratory panel (RP), and Diasorin Simplexa Flu A/B & RSV (Simplexa). Nasopharyngeal (NP) swab specimens (n = 225) from children previously tested by RP were assessed on these platforms. The results were compared to those of the Centers for Disease Control and Prevention (CDC)-developed real-time reverse transcription-PCR (rRT-PCR) assay for influenza A/B viruses and RSV. Subtyping for FluA and FluB was performed for discrepant analysis where applicable. The percent sensitivities/specificities for FluA detection were 100/100 (Fusion), 98.6/99.3 (Xpert), 100/100 (Liat), 98.6/100 (Aries), 98.6/100 (Simplexa), and 100/100 (RP). The percent sensitivities/specificities for FluB detection were 100/100 (Fusion), 97.9/99.4 (Xpert), 97.9/98.3 (Liat), 93.7/99.4 (Aries), 85.4/99.4 (Simplexa), and 95.8/97.7 (RP); and those for RSV detection were 98.1/99.4 (Xpert), 98.1/99.4 (Liat), 96.3/100 (Fusion), 94.4/100 (Aries), 87/94.4 (Simplexa), and 94.4/100 (RP). The 75 strains confirmed to be FluA included 29 pH1N1, 39 H3N2, 4 sH1N1, and 3 untyped strains. The 48 strains confirmed to be FluB included 33 strains of the Yamagata lineage, 13 of the Victoria lineage, 1 of both the Yamagata and Victoria lineages, and 1 of an unknown lineage. All six STA platforms demonstrated >95% sensitivity for FluA detection, while three platforms (Fusion, Xpert, and Liat) demonstrated >95% sensitivity for FluB and RSV detection.
引用
- Banerjee D, Kanwar N, Hassan F, et al. Comparison of Six Sample-to-Answer Influenza A/B and Respiratory Syncytial Virus Nucleic Acid Amplification Assays Using Respiratory Specimens from Children. J Clin Microbiol. 2018. PMID: 30185508. doi:10.1128/JCM.00930-18
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。