文献速递临床微生物质量管理与危急值

博德特菌污染血小板浓缩物:重新审视阳性培养定义

Bordetella holmesii Contamination of Platelet Concentrates: Revisiting the Definition of a Positive Culture.
PubMed 文献 · J Clin Microbiol · 2018-11-27

本文首次报告了博德特菌污染的血小板浓缩物,并研究了该菌在血小板浓缩物中的体外生长特性。两株从血小板浓缩物中分离的博德特菌及一株对照菌(粘质沙雷菌)以1和10 CFU/ml接种至血小板浓缩物,在20-24°C振荡储存,于第2、3、4、7天取样进行菌落计数和BacT/Alert 3D系统筛查。两袋血小板浓缩物检测为博德特菌阳性,但复培养阴性;体外博德特菌不生长但仍可检测到,与人血浆接触后活力迅速下降;BacT/Alert 3D筛查多数接种博德特菌的产品为阴性。

要点

  • 博德特菌可在血小板浓缩物中存活并保持休眠,导致BacT/Alert 3D系统检测困难。
  • 当前血小板浓缩物真阳性培养的定义对某些菌株可能过于严格。
  • 复培养阴性不能完全排除博德特菌污染,需考虑替代确认方法。

核心结论

  • 博德特菌可在血小板浓缩物中存活并保持休眠,导致BacT/Alert 3D系统检测困难。
  • 当前血小板浓缩物真阳性培养的定义对某些细菌菌株可能过于严格。

研究设计与样本

  • 研究将两株从血小板浓缩物中分离的博德特菌及一株对照菌(粘质沙雷菌)以1和10 CFU/ml接种至血小板浓缩物。
  • 血小板浓缩物在20至24°C振荡储存,于第2、3、4、7天取样进行菌落计数和BacT/Alert 3D系统筛查。

主要发现

  • 两袋血小板浓缩物检测为博德特菌阳性,但复培养阴性。
  • 体外博德特菌不生长但仍可在血小板浓缩物中检测到。
  • 博德特菌与人血浆接触后活力迅速下降。
  • BacT/Alert 3D系统筛查中,多数接种博德特菌的产品为阴性。

临床怎么用

  • 对于博德特菌污染的血小板浓缩物,BacT/Alert 3D系统筛查可能出现假阴性,需结合复培养或其他方法确认。
  • 当前阳性培养定义可能需重新评估,以避免漏检某些休眠或低浓度细菌。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Bacterial contamination remains the most important infectious risk of platelet transfusion. After an initially positive result, a second test is performed on the blood products and the initial culture bottle to confirm the contamination. Based on the blood center's decision algorithm used, results can be either confirmed negative, positive, or indeterminate, or be unconfirmed or discordant. Here, we report the first cases of platelet concentrates contaminated with Bordetella holmesii The in vitro growth characteristics of this unusual contaminant in platelet concentrate were investigated. Two B. holmesii strains isolated from platelet concentrates, as well as a control strain (Serratia marcescens), were spiked into platelet concentrates (PCs) at 1 and 10 CFU/ml. PCs were stored at 20 to 24°C under agitation. Samples were collected on days 2, 3, 4, and 7 for colony count and for bacterial screening using the BacT/Alert 3D system. Two PCs were detected as being positive for B. holmesii However, recultures were negative. In vitro, B. holmesii did not grow but remained detectable in PCs. Its viability diminished rapidly in contact with human plasma. Upon screening using the BacT/Alert 3D system, the majority of products spiked with B. holmesii were negative. This is the first description of PCs contaminated with B. holmesii This bacterium survives in blood products and remains dormant at low concentrations in blood products stored at room temperature, thus making difficult its detection with the BacT/Alert 3D system. The present definition of a true-positive culture of PCs may be overly restrictive for certain bacterial strains.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Cloutier M, Nolin MÈ, Daoud H, et al. Bordetella holmesii Contamination of Platelet Concentrates: Revisiting the Definition of a Positive Culture. J Clin Microbiol. 2018. PMID: 30158191. doi:10.1128/JCM.01105-18

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。