基于MALDI-TOF MS的靶上微滴生长法快速直接检测阳性血培养药敏
该研究探索将靶上微滴生长法(DOT-MGA)直接应用于阳性血培养以加速脓毒症诊断。用美罗培南敏感和非敏感肠杆菌目菌株模拟血培养,比较四种前处理方法,以裂解/离心法4小时培养表现最佳,有效度96.3%、敏感度91.7%、特异度100%。该方法可行且准确,并可同时进行菌种鉴定。
要点
- 裂解/离心法处理阳性血培养后4小时DOT-MGA性能最佳
- 有效度96.3%、敏感度91.7%、特异度100%
- 该方法可同步进行菌种鉴定与药敏检测
核心结论
- 从阳性血培养直接进行DOT-MGA快速药敏检测可行且准确。
研究设计与样本
- 用美罗培南敏感和非敏感肠杆菌目菌株模拟血培养,比较过滤/稀释、稀释、裂解/离心和差异离心四种前处理方法。
主要发现
- 裂解/离心法4小时培养表现最佳,有效度96.3%、敏感度91.7%、特异度100%。
- 稀释法在1:100、1:1,000和1:10,000稀释度下进行药敏检测。
- 离心法从菌体沉淀制备0.5麦氏浊度悬液,调整至5×10^5 CFU/ml的最终接种量。
关键数值与推荐
- 生长对照鉴定评分≥1.7视为试验有效。
- 含美罗培南孔鉴定成功(评分≥1.7)判为非敏感,失败(评分<1.7)判为敏感。
临床怎么用
- 阳性血培养可考虑用裂解/离心法处理,4小时孵育后行DOT-MGA快速药敏。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The recently developed direct-on-target microdroplet growth assay (DOT-MGA) allows rapid universal antimicrobial susceptibility testing (AST) using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Here, we investigated a direct application of this method on positive blood cultures (BCs) for the acceleration of sepsis diagnostics. Blood samples spiked with meropenem-nonsusceptible and meropenem-susceptible Enterobacterales isolates were inoculated into Bactec Plus Aerobic/F bottles and incubated in the Bactec automated system. Positive-BC broth was processed using four different methods, filtration/dilution, dilution, lysis/centrifugation, and differential centrifugation. For both dilution-based methods, AST was performed from 1:100, 1:1,000, and 1:10,000 dilutions of positive-BC broth in cation-adjusted Mueller-Hinton broth (CA-MHB). For both centrifugation-based methods, a 0.5 McFarland standard turbidity suspension was prepared from a bacterial pellet and adjusted to a final inoculum of 5 × 105 CFU/ml in CA-MHB. Six-microliter microdroplets with or without meropenem at the breakpoint concentration were spotted in triplicate onto a MALDI-TOF MS target, followed by incubation in a humidity chamber for 3 or 4 h and subsequent broth removal. Spectra were evaluated by MALDI Biotyper software. The test was considered valid if the growth control without antibiotic achieved an identification score of ≥1.7. For samples with meropenem, successful identification (score, ≥1.7) was interpreted as a nonsusceptible result, whereas failed identification (score, <1.7) defined susceptibility. The best test performance was achieved with the lysis/centrifugation method after a 4-h incubation. At this time point, 96.3% validity, 91.7% sensitivity, and 100% specificity were reached. This study demonstrated the feasibility and accuracy of a rapid DOT-MGA from positive BCs. Parallel to susceptibility determination, this method provides simultaneous species identification.
引用
- Idelevich EA, Storck LM, Sparbier K, et al. Rapid Direct Susceptibility Testing from Positive Blood Cultures by the Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based Direct-on-Target Microdroplet Growth Assay. J Clin Microbiol. 2018. PMID: 30093392. doi:10.1128/JCM.00913-18
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。