ISO 9001与ISO 15189质量体系对实验室性能正面影响的证据:奥地利19年免疫血液学室间质评结果评估
该研究回顾性分析1999-2017年奥地利红细胞免疫血液学室间质评中167家实验室的52,000余项结果,比较有无ISO 9001或ISO 15189认证/认可的质量体系及实验室类型的错误率。结果显示有质量体系实验室错误率为0.7%,无质量体系为1.4%(p=0.0002);实施ISO 9001/ISO 15189后错误率从1.3%降至0.7%(p=0.0468);输血服务机构错误率0.9%,医院和独立实验室均为1.2%。结论认为建立并维持ISO质量体系及实验室专业化可带来更好的分析性能。
要点
- 有ISO 9001或ISO 15189认证/认可的实验室室间质评错误率为0.7%,无质量体系者为1.4%(p=0.0002)。
- 实施ISO 9001/ISO 15189后错误率从1.3%降至0.7%(p=0.0468)。
- 输血服务机构错误率0.9%,低于医院和独立实验室的1.2%。
核心结论
- 建立并维持ISO 9001或ISO 15189质量体系以及实验室专业化可带来更好的分析性能,体现于免疫血液学室间质评结果。
研究设计与样本
- 回顾性分析1999-2017年奥地利红细胞免疫血液学室间质评方案59次分布中167家实验室的结果。
主要发现
- 分析超过52,000项室间质评结果,有ISO 9001或ISO 15189认证/认可的实验室错误率为0.7%,无此类质量体系者为1.4%(p=0.0002)。
- 实施ISO 9001/ISO 15189后错误率从1.3%降至0.7%(p=0.0468)。
- 输血服务机构错误率为0.9%,医院和独立实验室均为1.2%。
临床怎么用
- 检验科可参照ISO 9001或ISO 15189建立并维持质量体系,以改善室间质评分析性能。
- 输血服务机构专业化可能有助于降低室间质评错误率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background ISO 9001 and ISO 15189 have been established as continuative models for quality systems beyond national laws, mandatory standards and guidelines of expert associations regarding analytical and organisational performance of medical laboratories and transfusion services. Although widely used, their impact on laboratory performance has not been investigated. Methods We retrospectively analysed the results of 167 laboratories in 59 distributions of the Austrian red cell immunohaematology external quality assessment (EQA) scheme in the years 1999-2017. The performance for each parameter and trends of individual participants were compared with respect to certification or accreditation status of participants' quality systems and to laboratory type. Results Considering more than 52,000 EQA results, the absence or presence of a laboratory quality management system showed different error rates. Laboratories with ISO 9001 or ISO 15189 certification/accreditation had 0.7% incorrect results, while this rate was doubled without such quality systems (1.4%, p=0.0002). Statistically significant error reductions were seen upon ISO 9001/ISO 15189 implementation (1.3% before vs. 0.7% after; p=0.0468). Transfusion services had fewer errors (0.9%) compared to hospital and independent laboratories (both 1.2%). Conclusions Implementation and maintenance of quality systems according to ISO 9001 or ISO 15189 as well as laboratory specialisation result in better analytical performance as can be seen in immunohaematology EQA results. The conclusion is that these results apply to other laboratory tests and perhaps to other areas of health care.
引用
- Buchta C, Coucke W, Mayr WR, et al. Evidence for the positive impact of ISO 9001 and ISO 15189 quality systems on laboratory performance - evaluation of immunohaematology external quality assessment results during 19 years in Austria. Clin Chem Lab Med. 2018. PMID: 30016273. doi:10.1515/cclm-2018-0482
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。