HemaSpot与Whatman 903干血斑中HIV血清学标志物的稳定性比较

Stability of Human Immunodeficiency Virus Serological Markers in Samples Collected as HemaSpot and Whatman 903 Dried Blood Spots.
PubMed 文献 · J Clin Microbiol · 2018-09-25

该研究比较了HemaSpot-HF(HS)与Whatman 903(903)干血斑装置在检测HIV血清学标志物时的性能。使用已知临床标本和HIV血清转换盘,通过Bio-Rad GS HIV Combo Ag/Ab EIA、GS HIV-1/-2 Plus O EIA、GS HIV-1 Western blot和HIV-1 Geenius检测。两者在室温下稳定长达6个月,但在37-45°C、95%湿度下存放180天后,早期感染样本的Western blot和低滴度抗体信号明显丢失。HS加干燥剂密封袋可防止降解,信号恢复优于903,且HS更易用,对早期感染样本灵敏度和重现性更高。

要点

  • HS与903干血斑在室温下稳定存放6个月,适合远程地区HIV检测。
  • 高温高湿(37-45°C,95%湿度)存放180天导致早期感染样本Western blot和低滴度抗体信号明显丢失。
  • HS加干燥剂密封袋可保护样本免受降解,信号恢复优于903,且对早期感染灵敏度更高。

核心结论

  • HS和903干血斑在室温下稳定6个月,但高温高湿条件下早期感染标志物易降解;HS加干燥剂可改善稳定性与信号恢复。

研究设计与样本

  • 使用已表征的临床标本和HIV血清转换盘,制备HS和903干血斑,用四种HIV检测方法比较性能。

主要发现

  • HS和903在室温下稳定长达6个月。
  • 37-45°C、95%湿度下存放180天,早期感染样本的Western blot和低滴度抗体信号明显丢失。
  • HS加干燥剂密封袋可防止降解,信号恢复优于903。
  • HS比903更易使用,对早期感染样本灵敏度和重现性更高。

临床怎么用

  • 在远程地区或需长期保存干血斑时,优先选用HS并加干燥剂密封,以提高早期HIV感染检测的可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Dried blood spots (DBS) are frequently used in clinical testing for biosurveillance, infectious disease and confirmatory testing, and clinical trials, particularly for populations in remote areas. The HemaSpot-HF blood collection device (HS) provides an alternative format to the Whatman 903 cards (903) to simplify sample collection and processing. In this study, the performance of the HS was compared to that of the 903 using previously characterized clinical specimens and HIV seroconversion panels known to exhibit markers of early human immunodeficiency virus (HIV) infection. HS and 903 samples were prepared and tested by Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay (EIA), GS HIV-1/-2 Plus O EIA, GS HIV-1 Western blot, and HIV-1 Geenius assays. Both HS and 903 performed well for up to 6 months at room temperature, but a marked loss of Western blot and low titer antibody signals from early infection samples was observed in samples stored for 180 days at elevated (37 to 45°C) temperatures and high humidity (95%). HemaSpot samples placed in sealed bags with additional desiccant were protected from degradation and showed improved signal recovery relative to that of the 903. HS was easier to use than the 903 and showed higher sensitivity and reproducibility for early infection samples and improved stability.