文献速递临床微生物质量管理与危急值

SensiTest Colistin 肉汤微量稀释法检测黏菌素 MIC 的临床验证

Clinical Validation of SensiTest Colistin, a Broth Microdilution-Based Method To Evaluate Colistin MICs.
PubMed 文献 · J Clin Microbiol · 2018-03-26

该研究评估基于肉汤微量稀释(BMD)的商用检测 SensiTest Colistin(STC)与 EUCAST-CLSI 参考 BMD 法的一致性,共测试 353 株菌,其中 137 株对黏菌素耐药。结果显示 STC 与 BMD 的基本一致率为 96.0%,分类一致率为 98.9%,对携带 mcr-1 基因菌株的基本一致率为 98.8%。

要点

  • STC 与参考 BMD 法分类一致率达 98.9%,基本一致率 96.0%。
  • STC 对携带 mcr-1 基因菌株的基本一致率为 98.8%。
  • Phoenix 100 系统在部分菌株中记录了 10% 的重大误差。

核心结论

  • SensiTest Colistin 是一种简单且高度可靠的黏菌素药敏检测方法,具有良好的可重复性。

研究设计与样本

  • 研究比较了基于 BMD 的商用检测 STC 与 EUCAST-CLSI 标准参考 BMD 法,部分菌株还与自动化 Phoenix 100 系统比较;共 353 株细菌由两个不同实验室评估,其中 137 株对黏菌素耐药(19 株天然耐药,83 株携带 mcr-1 基因)。

主要发现

  • STC 与 BMD 的基本一致率为 96.0%(339/353),总体分类一致率为 98.9%(349/353)。
  • 记录了 2 个重大误差(0.93%)和 2 个极重大误差(1.46%)。
  • STC 在室温或 35°C 储存面板下仍具有良好的可重复性。
  • STC 对携带 mcr-1 基因菌株的基本一致率为 98.8%。
  • Phoenix 100 系统在 6 株菌(10%)中记录了极重大误差。

关键数值与推荐

  • STC 面板含 7 个二倍稀释浓度(0.25 至 16 μg/ml)的冻干抗生素。
  • 基本一致率 96.0%,分类一致率 98.9%,重大误差 0.93%,极重大误差 1.46%。

临床怎么用

  • STC 可作为基于 BMD 的黏菌素药敏检测选项,尤其适用于携带 mcr-1 基因菌株的检测。

局限性

  • 原文未明确报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The global spread of multidrug-resistant Gram-negative bacteria has led to the return of colistin for treating severe infections. Recently, different plasmid-mediated genes conferring resistance to this drug were described and reported worldwide. International committees (EUCAST/CLSI) reevaluated inconsistencies surrounding colistin antimicrobial susceptibility testing (AST), concluding that broth microdilution (BMD) should serve as the reference method for AST. The development of an accurate, reproducible commercial test based on BMD is therefore highly desirable. SensiTest Colistin (STC), a BMD-based compact 4-test panel containing the lyophilized antibiotic in 7 2-fold dilutions (0.25 to 16 μg/ml) was here compared with the EUCAST-CLSI standard reference method (BMD) and, for some isolates, with the automated Phoenix 100 system (PHX). A total of 353 bacterial strains were evaluated by two different laboratories; 137 isolates were resistant to colistin (19 were intrinsically resistant, 83 harbored the mcr-1 gene). Essential agreement (EA) between STC and BMD was obtained for 339 out of the 353 strains tested (96.0%). Overall categorical agreement was obtained for 349 out of the 353 strains analyzed (98.9%). Two major errors (MEs; 0.93%) and two very major errors (VMEs; 1.46%) were documented. STC appeared to be a simple but highly reliable test with good reproducibility even with panels stored at room temperature or at 35°C. Moreover, STC showed a good performance with strains carrying the mcr-1 gene, with a 98.8% EA. As the secondary endpoint of our study, VMEs for PHX were documented for 6 isolates (10%).

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Carretto E, Brovarone F, Russello G, et al. Clinical Validation of SensiTest Colistin, a Broth Microdilution-Based Method To Evaluate Colistin MICs. J Clin Microbiol. 2018. PMID: 29343542. doi:10.1128/JCM.01523-17

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。