文献速递临床免疫分子诊断

广谱多聚omavirus IgG血清反应多重免疫分析法的开发与评估

Development and Evaluation of a Broad Bead-Based Multiplex Immunoassay To Measure IgG Seroreactivity against Human Polyomaviruses.
PubMed 文献 · J Clin Microbiol · 2018-03-26

为检测所有已知人类多聚omavirus(HPyV)的IgG血清反应,研究扩展了基于荧光微球的多重免疫分析法,使用15种HPyV的VP1蛋白偶联微球,在健康献血者和免疫抑制肾移植受者中评估性能;该法重复性好(Pearson r² > 0.84,P < 0.001)、特异性强,与VLP-ELISA高度相关(Spearman ρ = 0.823,P < 0.001)。

要点

  • 基于GST-VP1融合蛋白的Luminex多重免疫分析法可同时检测15种HPyV的IgG血清反应。
  • 该法重复性好(r² > 0.84,P < 0.001)且特异性强,与VLP-ELISA高度相关(ρ = 0.823,P < 0.001)。
  • 多数HPyV血清反应常见且水平高,但HPyV9、HPyV12、New Jersey PyV和LIPyV反应低。

核心结论

  • 基于微球的泛HPyV多重免疫分析法可靠、重复性高、特异性强,适用于血清流行病学研究。

研究设计与样本

  • 将15种HPyV(13个多聚omavirus种)的VP1蛋白表达为GST融合蛋白并偶联荧光Luminex微球。
  • 使用健康献血者和免疫抑制肾移植受者的血清分析对不同HPyV的血清反应。

主要发现

  • 多数HPyV的血清反应在两组人群中常见且普遍较高。
  • HPyV9、HPyV12、New Jersey PyV和LIPyV的血清反应较低。
  • HPyV6与HPyV7之间存在弱但一致的交叉反应。
  • 该法重复性好(Pearson r² > 0.84,P < 0.001)且特异性强。
  • GST-VP1法与VLP-ELISA结果高度相关(Spearman ρ = 0.823,P < 0.001)。

关键数值与推荐

  • 重复性以Pearson r² > 0.84(P < 0.001)评估。
  • 与VLP-ELISA相关性以Spearman ρ = 0.823(P < 0.001)评估。

临床怎么用

  • 可用于HPyV特异性血清反应的检测及血清流行病学研究。

局限性

  • 观察到HPyV6与HPyV7之间存在弱但一致的交叉反应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The family of polyomaviruses, which cause severe disease in immunocompromised hosts, has expanded substantially in recent years. To accommodate measurement of IgG seroresponses against all currently known human polyomaviruses (HPyVs), including the Lyon IARC polyomavirus (LIPyV), we extended our custom multiplex bead-based HPyV immunoassay and evaluated the performance of this pan-HPyV immunoassay. The VP1 proteins of 15 HPyVs belonging to 13 Polyomavirus species were expressed as recombinant glutathione S-transferase (GST) fusion proteins and coupled to fluorescent Luminex beads. Sera from healthy blood donors and immunocompromised kidney transplant recipients were used to analyze seroreactivity against the different HPyVs. For BK polyomavirus (BKPyV), the GST-VP1 fusion protein-directed seroresponses were compared to those obtained against BKPyV VP1 virus-like particles (VLP). Seroreactivity against most HPyVs was common and generally high in both test populations. Low seroreactivity against HPyV9, HPyV12, New Jersey PyV, and LIPyV was observed. The assay was reproducible (Pearson's r2 > 0.84, P < 0.001) and specific. Weak but consistent cross-reactivity between the related viruses HPyV6 and HPyV7 was observed. The seroresponses measured by the GST-VP1-based immunoassay and a VP1 VLP-based enzyme-linked immunosorbent assay were highly correlated (Spearman's ρ = 0.823, P < 0.001). The bead-based pan-HPyV multiplex immunoassay is a reliable tool to determine HPyV-specific seroresponses with high reproducibility and specificity and is suitable for use in seroepidemiological studies.