文献速递临床生化质量管理与危急值

尿液游离皮质醇的四种LC-MSMS方法比较

LC-MSMS assays of urinary cortisol, a comparison between four in-house assays.
PubMed 文献 · Clin Chem Lab Med · 2018-01-01

研究将78名健康志愿者和20例库欣综合征患者的24小时尿液样本分发至四个独立实验室,用四种LC-MSMS法测定尿游离皮质醇。各中心批内和批间变异系数均低于10%,外部质控结果无显著差异,但极端值(<50或>270 nmol/day)存在偏差,提示方法需验证并建立参考范围。

要点

  • 四种LC-MSMS法批内和批间变异系数均低于10%。
  • 健康志愿者UFC正常范围各中心不同,分别为17-126、15-134、12-118和27-157 nmol/day。
  • 极端UFC值(<50或>270 nmol/day)可出现负偏或正偏。

核心结论

  • 即使使用高特异性的LC-MSMS方法,不同分析过程仍可导致UFC结果差异,方法验证和参考范围建立至关重要。

研究设计与样本

  • 四个独立实验室对78名健康志愿者和20例库欣综合征患者的24小时尿液冻存样本,分别采用四种LC-MSMS法测定UFC。

主要发现

  • 各中心UFC批内和批间变异系数均低于10%。
  • 外部质控结果无显著差异。
  • 各中心建立的UFC正常范围分别为17-126、15-134、12-118和27-157 nmol/day。
  • 以第95百分位数阈值分类健康志愿者和库欣综合征患者的结果相似。
  • 极端UFC值(<50或>270 nmol/day)存在负偏或正偏。

关键数值与推荐

  • 各中心UFC批内和批间变异系数均低于10%。
  • 健康志愿者UFC正常范围分别为17-126、15-134、12-118和27-157 nmol/day。
  • 分类阈值采用第95百分位数。
  • 极端值界定为<50或>270 nmol/day。

临床怎么用

  • 实验室应验证LC-MSMS方法并建立本中心参考范围。
  • 解读UFC极端值(<50或>270 nmol/day)时需考虑方法偏差。

局限性

  • 样本量有限(78名健康志愿者和20例库欣综合征患者)。
  • 仅比较四种LC-MSMS方法,未涉及其他检测平台。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Twenty-four hour urinary free cortisol (UFC) determination can be used for screening and follow-up of Cushing syndrome (CS). As immunoassay methods lack specificity for UFC measurement, the use of high-performance liquid chromatography coupled to mass spectrometer (LC-MSMS) is recommended. The aim of our study was to compare UFC results using four LC-MSMS methods performed in four independent laboratories in order to evaluate interlaboratory agreement. METHODS: Frozen aliquots of 24-h urine samples (78 healthy volunteers and 20 patients with CS) were sent to four different laboratories for analysis. Following liquid-liquid or solid-liquid extraction, UFC were determined using four different LC-MSMS assay. RESULTS: UFC intra- and interassays variation coefficients were lower than 10% for each centre. External quality control results were not significantly different. UFC normal ranges (established from healthy volunteers) were 17-126, 15-134, 12-118 and 27-157 nmol/day, respectively. Classification of UFC from healthy volunteers and patients with CS using a 95th percentile threshold was similar. However, for extreme UFC values (<50 or >270 nmol/day), negative or positive bias was noted. CONCLUSIONS: Even for highly specific methods such as LC-MSMS, variations of results can be found depending on analytical process. Validation of LC-MSMS methods including determination of the reference range is essential.