文献速递临床微生物分子诊断

评估CLSI苯唑西林和头孢西丁纸片扩散与MIC折点检测施莱弗葡萄球菌mecA介导的苯唑西林耐药

Evaluation of Oxacillin and Cefoxitin Disk Diffusion and MIC Breakpoints Established by the Clinical and Laboratory Standards Institute for Detection of mecA-Mediated Oxacillin Resistance in Staphylococcus schleiferi.
PubMed 文献 · J Clin Microbiol · 2018-01-24

本研究评估了CLSI苯唑西林和头孢西丁纸片扩散法与MIC折点检测52株人源和38株兽医源施莱弗葡萄球菌中mecA介导的苯唑西林耐药。结果显示,采用假中间葡萄球菌折点的苯唑西林纸片扩散或MIC方法能可靠区分mecA阳性与阴性菌株(CA 100%),而头孢西丁方法表现不佳。

要点

  • 苯唑西林纸片扩散或MIC采用假中间葡萄球菌折点可可靠检测mecA介导的耐药。
  • 头孢西丁纸片扩散和MIC方法在施莱弗葡萄球菌中表现差。
  • 90株菌中32%为mecA阳性,需关注其耐药性。

核心结论

  • 采用当前假中间葡萄球菌折点的苯唑西林纸片扩散或MIC方法能可靠识别施莱弗葡萄球菌中mecA介导的苯唑西林耐药。
  • 头孢西丁纸片扩散和MIC方法在检测施莱弗葡萄球菌mecA介导耐药时表现不佳。

研究设计与样本

  • 研究纳入52株人源和38株兽医源施莱弗葡萄球菌分离株,共90株。
  • 采用多个商业培养基品牌,按CLSI方法进行纸片扩散和MIC检测。
  • 以mecA PCR结果作为参考方法进行比较。

主要发现

  • 苯唑西林纸片扩散和MIC采用假中间葡萄球菌折点解释时,分类一致率为100%,所有培养基均无极重大误差和重大误差。
  • 头孢西丁纸片扩散采用金黄色葡萄球菌/路邓葡萄球菌折点解释时,分类一致率为85%,极重大误差为72%;采用凝固酶阴性葡萄球菌折点解释时,分类一致率为75%,极重大误差为64%。
  • 头孢西丁MIC采用金黄色葡萄球菌/路邓葡萄球菌折点解释时,分类一致率为81%,极重大误差为60%。
  • 头孢西丁纸片扩散和MIC均无重大误差。

关键数值与推荐

  • CLSI M100-S27(2017)折点用于解释结果。
  • 苯唑西林采用假中间葡萄球菌折点:分类一致率100%,无极重大误差和重大误差。
  • 头孢西丁纸片扩散采用金黄色葡萄球菌/路邓葡萄球菌折点:分类一致率85%,极重大误差72%。
  • 头孢西丁纸片扩散采用凝固酶阴性葡萄球菌折点:分类一致率75%,极重大误差64%。
  • 头孢西丁MIC采用金黄色葡萄球菌/路邓葡萄球菌折点:分类一致率81%,极重大误差60%。

临床怎么用

  • 对于施莱弗葡萄球菌,应使用苯唑西林纸片扩散或MIC方法并采用假中间葡萄球菌折点来检测mecA介导的苯唑西林耐药。
  • 不宜使用头孢西丁纸片扩散或MIC方法检测施莱弗葡萄球菌的mecA介导耐药。

局限性

  • 纸片扩散和MIC结果受所用商业培养基品牌影响,但苯唑西林方法在所有培养基上表现一致。
  • 头孢西丁方法表现不佳,可能受折点解释标准不适用影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Staphylococcus schleiferi is a beta-hemolytic, coagulase-variable colonizer of small animals that can cause opportunistic infections in humans. In veterinary isolates, the rate of mecA-mediated oxacillin resistance is significant, with reported resistance rates of >39%. The goal of this study was to evaluate oxacillin and cefoxitin disk diffusion (DD) and MIC breakpoints for detection of mecA-mediated oxacillin resistance in 52 human and 38 veterinary isolates of S. schleiferi Isolates were tested on multiple brands of commercial media and according to Clinical and Laboratory Standards Institute (CLSI) methods. Zone diameters and MIC values were interpreted using CLSI breakpoints (CLSI, Performance Standards for Antimicrobial Susceptibility Testing. M100-S27, 2017) for Staphylococcus aureus/Staphylococcus lugdunensis, coagulase-negative staphylococci (CoNS), and Staphylococcus pseudintermedius Results were compared to those of mecA PCR. Twenty-nine of 90 (32%) isolates were mecA positive. Oxacillin inhibition zone sizes and MICs interpreted by S. pseudintermedius breakpoints reliably differentiated mecA-positive and mecA-negative isolates, with a categorical agreement (CA) of 100% and no very major errors (VMEs) or major errors (MEs) for all media. For cefoxitin DD results interpreted using S. aureus/S. lugdunensis and CoNS breakpoints, CA values were 85% and 75%, respectively, and there were 72% and 64% VMEs, respectively, and 0 MEs. For cefoxitin MICs interpreted using S. aureus/S. lugdunensis breakpoints, CA was 81%, and there were 60% VMEs and no MEs. Our data demonstrate that oxacillin DD or MIC testing methods using the current S. pseudintermedius breakpoints reliably identify mecA-mediated oxacillin resistance in S. schleiferi, while cefoxitin DD and MIC testing methods perform poorly.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Huse HK, Miller SA, Chandrasekaran S, et al. Evaluation of Oxacillin and Cefoxitin Disk Diffusion and MIC Breakpoints Established by the Clinical and Laboratory Standards Institute for Detection of mecA-Mediated Oxacillin Resistance in Staphylococcus schleiferi. J Clin Microbiol. 2018. PMID: 29187565. doi:10.1128/JCM.01653-17

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。