Xpert MRSA NxG 检测鼻拭子中耐甲氧西林金黄色葡萄球菌的多中心评估
该多中心研究评估 Xpert MRSA NxG 检测鼻拭子中 MRSA 的临床性能,以前瞻性收集的棉签拭子(n=1,103)和植绒拭子(n=846)为样本,以培养法和药敏试验为参考标准。结果显示棉签拭子灵敏度和特异度分别为 91.0% 和 96.9%,植绒拭子为 92.9% 和 97.6%,合并数据为 91.8% 和 97.2%。结论认为该检测是灵敏且特异的直接检测方法。
要点
- Xpert MRSA NxG 检测鼻拭子 MRSA 的合并灵敏度 91.8%、特异度 97.2%。
- 棉签拭子阳性预测值 78.7%,植绒拭子阳性预测值 83.5%。
- 两种拭子阴性预测值均高(98.9% 和 99.1%),适合排除定植。
核心结论
- Xpert MRSA NxG 检测是灵敏且特异的鼻拭子 MRSA 直接检测方法。
研究设计与样本
- 多中心评估,前瞻性收集棉签鼻拭子 n=1,103 和植绒拭子(ESwab)鼻标本 n=846,以培养法和抗菌药物敏感性试验为参考标准。
主要发现
- 参考方法显示 MRSA 阳性率:棉签拭子 11.1%(122/1,103),植绒拭子 11.6%(98/846)。
- 棉签拭子在 8 个测试点灵敏度 91.0%(95%CI 84.6–94.9%),特异度 96.9%(95%CI 95.7–97.8%)。
- 植绒拭子在 6 个测试点灵敏度 92.9%(95%CI 86.0–96.5%),特异度 97.6%(95%CI 96.2–98.5%)。
- 合并数据灵敏度 91.8%(95%CI 87.4–94.8%),特异度 97.2%(95%CI 96.3–97.9%)。
- 棉签拭子阳性预测值 78.7%,植绒拭子 83.5%;阴性预测值分别为 98.9% 和 99.1%。
临床怎么用
- 可用于鼻拭子标本直接检测 MRSA 定植,辅助感染控制实践。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Health care-associated methicillin-resistant Staphylococcus aureus (MRSA) infections are a burden on the health care system. Clinical laboratories play a key role in reducing this burden, as the timely identification of MRSA colonization or infection facilitates infection control practices that are effective at limiting invasive MRSA infections. The Xpert MRSA NxG assay recently received FDA clearance for the direct detection of MRSA from nasal swabs. This multicenter study evaluated the clinical performance characteristics of the Xpert MRSA NxG assay with prospectively collected rayon nasal swabs (n = 1,103) and flocked swab (ESwab) nasal specimens (n = 846). Culture-based identification methods and antimicrobial susceptibility testing were used as the reference standards for comparison. According to the reference method, the positivity rates for MRSA in the population evaluated were 11.1% (122/1,103) for rayon swabs and 11.6% (98/846) for flocked swabs. The overall sensitivity and specificity of the rayon swabs were 91.0% (95% confidence interval [CI], 84.6 to 94.9%) and 96.9% (95% CI, 95.7 to 97.8%), respectively, across eight testing sites. The flocked swab specimens were 92.9% sensitive (95% CI, 86.0 to 96.5%) and 97.6% specific (95% CI, 96.2 to 98.5%) for MRSA detection across six testing sites. The sensitivity and specificity of the combined flocked and rayon swab data were 91.8% (95% CI, 87.4 to 94.8%) and 97.2% (95% CI, 96.3 to 97.9%), respectively. The positive predictive value (PPV) for rayon swabs was 78.7%, versus 83.5% for ESwabs. The negative predictive values (NPVs) for rayon swabs and ESwab specimens were 98.9% and 99.1%, respectively. In conclusion, the Xpert MRSA NxG assay is a sensitive and specific assay for the direct detection of MRSA from nasal swab specimens.
引用
- Yarbrough ML, Warren DK, Allen K, et al. Multicenter Evaluation of the Xpert MRSA NxG Assay for Detection of Methicillin-Resistant Staphylococcus aureus in Nasal Swabs. J Clin Microbiol. 2017. PMID: 29118165. doi:10.1128/JCM.01381-17