文献速递临床微生物质量管理与危急值

全实验室自动化与MALDI-TOF质谱改善临床微生物实验室周转时间

Total Laboratory Automation and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Improve Turnaround Times in the Clinical Microbiology Laboratory: a Retrospective Analysis.
PubMed 文献 · J Clin Microbiol · 2017-12-26

该回顾性分析比较了实施Bruker MALDI-TOF MS和BD Kiestra全实验室自动化(TLA)前后尿培养周转时间(TAT)。比较I中61,157份尿培养显示TLA后鉴定、药敏及阴性初步报告TAT均显著缩短(P<0.001);比较II中5,402份阳性报告显示MALDI-TOF MS和TLA分别及联合显著缩短鉴定和药敏报告TAT。

要点

  • TLA使尿培养鉴定TAT中位数从18.5h降至16.9h,药敏从41.8h降至40.8h。
  • TLA使阴性培养初步报告TAT中位数从17.7h降至13.6h。
  • MALDI-TOF MS使鉴定TAT中位数从21.3h降至18h,TLA进一步降至16.5h。

核心结论

  • TLA显著改善尿培养鉴定、药敏报告和阴性初步结果的周转时间。
  • MALDI-TOF MS显著改善微生物鉴定周转时间。
  • 单独或联合使用MALDI-TOF MS与TLA均显著缩短微生物报告周转时间。

研究设计与样本

  • 回顾性分析,比较实施MALDI-TOF MS和TLA前后尿培养周转时间。
  • 比较I纳入61,157份尿培养,分TLA前和TLA后两个时期,均使用MALDI-TOF MS鉴定。
  • 比较II纳入5,402份阳性培养报告,涵盖传统生化鉴定、MALDI-TOF MS鉴定、TLA早期和TLA后期四个时期。

主要发现

  • 比较I中,TLA后鉴定TAT中位数由18.5h降至16.9h,药敏由41.8h降至40.8h,阴性初步报告由17.7h降至13.6h(P<0.001)。
  • 比较II中,MALDI-TOF MS较传统生化鉴定显著改善鉴定TAT(21.3h降至18h)。
  • TLA较MALDI-TOF MS进一步改善鉴定TAT(18h降至16.5h)和药敏TAT(42.3h降至40.7h)(P<0.001)。

关键数值与推荐

  • TLA后鉴定TAT中位数16.9h,药敏40.8h,阴性初步报告13.6h。
  • MALDI-TOF MS鉴定TAT中位数18h,TLA后进一步降至16.5h。
  • TLA后药敏TAT中位数40.7h,较MALDI-TOF MS的42.3h降低。

临床怎么用

  • 临床微生物实验室可联合应用MALDI-TOF MS与TLA以缩短尿培养鉴定和药敏报告时间。
  • 自动化与质谱技术有助于更快发出阴性初步报告,支持临床尽早调整经验性抗菌治疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Technological advances have changed the practice of clinical microbiology. We implemented Bruker matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and BD Kiestra total laboratory automation (TLA) 4 and 3 years ago, respectively. To assess the impact of these new technologies, we compared turnaround times (TATs) for positive and negative urine cultures before and after implementation. In comparison I, TATs for 61,157 urine cultures were extracted for two periods corresponding to pre-TLA and post-TLA, both using MALDI-TOF MS for organism identification. In comparison II, time to organism identification (ID) and antimicrobial susceptibility (AST) reports were calculated for 5,402 positive culture reports representing four different periods: (i) manual plating and conventional biochemical identification (CONV), (ii) manual plating and MALDI-TOF MS identification (MALDI), (iii) MALDI-TOF MS identification and early phase implementation of TLA (TLA1), and (iv) MALDI-TOF MS identification and late phase implementation of TLA (TLA2). By the comparison I results, median pre- and post-TLA TATs to organism IDs (18.5 to 16.9 h), AST results (41.8 to 40.8 h), and preliminary results for negative cultures (17.7 to 13.6 h), including interquartile ranges for all comparisons, were significantly decreased post-TLA (P < 0.001). By the comparison II results, MALDI significantly improved TAT to organism ID compared to CONV (21.3 to 18 h). TLA further improved overall TAT to ID (18 to 16.5 h) and AST (42.3 to 40.7 h) results compared to MALDI (P < 0.001). In summary, TLA significantly improved TAT to organism ID, AST report, and preliminary negative results. MALDI-TOF MS significantly improved TAT for organism ID. Use of MALDI-TOF MS and TLA individually and together results in significant decreases in microbiology report TATs.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Theparee T, Das S, Thomson RB, et al. Total Laboratory Automation and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Improve Turnaround Times in the Clinical Microbiology Laboratory: a Retrospective Analysis. J Clin Microbiol. 2017. PMID: 29118171. doi:10.1128/JCM.01242-17