文献速递质量管理与危急值

斯坦福大学医学中心实施Epic Beaker临床病理模块的经验

Implementation of Epic Beaker Clinical Pathology at Stanford University Medical Center.
PubMed 文献 · Am J Clin Pathol · 2017-01-01

斯坦福大学医学中心基于正式选型流程,以Epic Beaker 2014临床病理模块替换Sunquest作为临床实验室信息系统。实施后检验周转时间较历史基线改善,主要归因于患者正身份识别(PPID);PPID也显著减少了标签错误标本。该系统功能可满足大型学术中心需求,优势包括PPID和与电子病历的整合。

要点

  • 实施PPID后检验周转时间较历史基线改善,并显著减少标签错误标本。
  • Epic Beaker与已装Epic电子病历整合,减少系统与接口数量,便于实验室用户获取临床病史。
  • 系统在标本分装、质量控制报告和维护工具方面仍需进一步开发。

核心结论

  • Epic 2014 Beaker临床病理模块是可行的实验室信息系统,对大型学术中心具备足够功能。

研究设计与样本

  • 斯坦福大学医学中心经正式选型流程选择Epic Beaker替换Sunquest作为临床实验室信息系统,并进行了大量定制及首个Epic-to-Epic接口建设。

主要发现

  • 检验周转时间较历史基线改善,主要因实施PPID。
  • PPID实施后标签错误标本显著减少。
  • 系统优势包括PPID及与电子病历整合,使实验室用户可即时获取患者相关临床病史以辅助结果发布。
  • 系统为医生和护士提供复杂的附加医嘱与标本采集工作流程。

临床怎么用

  • 大型学术中心可考虑采用Epic Beaker作为临床实验室信息系统,以利用PPID和电子病历整合优势。
  • 实施时应评估标本分装、质量控制报告和维护工具等功能的充分性。

局限性

  • 系统在标本分装、质量控制报告和维护工具方面有待进一步开发。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To provide an account of implementation of the Epic Beaker 2014 clinical pathology module at Stanford University Medical Center and highlight strengths and weaknesses of the system. METHODS: Based on a formal selection process, Stanford selected Epic Beaker to replace Sunquest as the clinical laboratory information system (LIS). The rationale included integration between the LIS and already installed Epic electronic medical record (EMR), reduction in the number of systems and interfaces, and positive patient identification (PPID). The build was significantly customized and included a first of its kind Epic-to-Epic interface. This was due to the clinical laboratory serving two hospitals (pediatric and adult) with independent instances of Epic. RESULTS: Test turnaround times showed improvement from historical baselines, mostly because of the implementation of PPID. PPID also resulted in significant reduction in mislabeled specimens. CONCLUSIONS: Epic 2014 Beaker clinical pathology is a viable LIS with adequate functionality for a large academic center. Strengths include PPID and integration with the EMR. Integration provides laboratory users with ready access to the patient's relevant clinical history to assist releasing of results and gives physician and nurse providers sophisticated add-on ordering and specimen collection workflows. Areas that could use further development include specimen aliquoting, quality control reporting, and maintenance tools.

来源:Am J Clin Pathol,查看原文。版权归原作者所有。

引用

  1. Tan BT, Fralick J, Flores W, et al. Implementation of Epic Beaker Clinical Pathology at Stanford University Medical Center. Am J Clin Pathol. 2017. PMID: 28395051. doi:10.1093/ajcp/aqw221

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。