文献速递临床生化临床免疫

万古霉素常规TDM的新LC-MS/MS方法:与FPIA在不同肌酐浓度下的比较

New liquid chromatography-tandem mass spectrometry method for routine TDM of vancomycin in patients with both normal and impaired renal functions and comparison with results of polarization fluoroimmunoassay in light of varying creatinine concentrations.
PubMed 文献 · Clin Chim Acta · 2017-04-07

本研究开发并验证了一种简便、快速的LC-MS/MS方法用于万古霉素常规治疗药物监测,并与FPIA法比较。按肌酐水平分三组,正常及中度升高肌酐组两法相关性很好,但最高肌酐的透析患者FPIA结果约高估14%,可能因代谢物CDP干扰,但认为无临床相关性。

要点

  • 新LC-MS/MS方法仅需50μL血清,前处理简单,分析时间较短。
  • 正常及中度肾功能不全患者中,LC-MS/MS与FPIA结果相关性很好。
  • 透析患者FPIA结果约高估14%,可能因代谢物CDP干扰,但无临床相关性。

核心结论

  • 新LC-MS/MS方法适用于万古霉素常规TDM,在正常及受损肾功能患者中与FPIA结果相关性好。
  • 最高肌酐的透析患者FPIA结果约高估14%,可能因代谢物CDP,但认为无临床相关性。

研究设计与样本

  • 方法学开发与验证研究,使用50μL血清经20μL 33%三氯乙酸沉淀并加0.5mol/L NH4OH调pH。
  • 色谱条件:RP BEH C18柱(1.7μm,2.1×50mm),30°C,替布霉素为内标,正离子电喷雾检测。
  • 受试者按肌酐水平分为三组(53.5±19.1、150.2±48.4、471.7±124.7μmol/L),用Passing-Bablok回归和Bland-Altman分析比较。

主要发现

  • 正常肌酐组线性回归方程:LC-MSVAN=0.947×AbbottVAN+0.192。
  • 中度升高肌酐组线性回归方程:LC-MSVAN=0.973×AbbottVAN-0.411。
  • 最高肌酐透析组FPIA结果约高估14%,回归方程:LC-MSVAN=0.866×AbbottVAN+2.127。

临床怎么用

  • 新LC-MS/MS方法可用于万古霉素常规TDM,尤其适用于肾功能正常或受损患者。
  • 透析患者中FPIA结果可能高估,但鉴于推荐浓度范围宽,认为无临床相关性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

A new LC-MS/MS method with simple sample extraction and a relatively short period of vancomycin analysis for routine therapeutic drug monitoring was developed and validated. 50μL serum was precipitated using 20μL 33% trichloroacetic acid and 0.5mol/L NH4OH was added to increase pH before analysis. A RP BEH C18, 1.7μm, 2.1×50mm column maintained at 30°C and tobramycin as internal standard were used. Mass detection was performed in positive electrospray mode. The results obtained with LC-MS/MS method were correlated with an FPIA assay (Abbott AxSYM) using mouse monoclonal antibody. Subjects were divided into three groups according to creatinine levels (53.5±19.1, 150.2±48.4, 471.7±124.7μmol/L) and Passing-Bablok regression analysis and Bland-Altman analysis were used to compare vancomycin concentrations. The results of subjects with both normal and higher creatinine levels correlated very well and the linear regression model equations were near ideal (LC-MSVAN=0.947×AbbottVAN+0.192 and LC-MSVAN=0.973×AbbottVAN-0.411 respectively). Dialyzed patients with the highest creatinine levels showed about 14% greater vancomycin concentration with the FPIA assay (LC-MSVAN=0.866×AbbottVAN+2.127). This overestimation probably due to the presence of the metabolite CDP ought not to be of clinical relevance owing to the wide range of recommended vancomycin concentration.

来源:Clin Chim Acta,查看原文。版权归原作者所有。

引用

  1. Brozmanová H, Kacířová I, Uřinovská R, et al. New liquid chromatography-tandem mass spectrometry method for routine TDM of vancomycin in patients with both normal and impaired renal functions and comparison with results of polarization fluoroimmunoassay in light of varying creatinine concentrations. Clin Chim Acta. 2017. PMID: 28392327. doi:10.1016/j.cca.2017.04.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。