在实验室室间质评中通过多样本评估表达分析性能
荷兰SKML室间质评组织在常规化学计划中引入新鲜冰冻可互换样本,其值由JCTLM列出的参考实验室用参考方法赋值。反馈报告在原有正确度和不精密度基础上,增加基于sigma值的性能指标,以判断是否正确度和不精密度符合预设分析性能规范。
要点
- 采用新鲜冰冻可互换样本和参考方法赋值,可评估正确度。
- Sigma值结合TEa和SA容差区间,评价正确度与不精密度。
- 反馈报告以图形和两点评分系统呈现性能评估结果。
核心结论
- 在室间质评计划中加入基于sigma指标、并关联TEa与SA容差区间的性能评估,可为参与者提供有力且可操作的正确度检查。
研究设计与样本
- 荷兰SKML对其常规化学室间质评计划进行创新,引入新鲜冰冻可互换样本,其值由JCTLM列出的参考实验室尽可能使用参考方法赋值。
主要发现
- 现有反馈报告通过最近12个月结果回归线与参考实验室值的一致性表达正确度,并从回归线残差计算不精密度。
- 新增的sigma值根据正确度与不精密度组合落在容差限内的程度计算。
- 信息及其两点评分系统结论在现有差异图之外还以图形呈现。
关键数值与推荐
- 容差区间基于生物学变异数据的总误差允许(TEa)和与EFLM米兰共识一致的最新水平(SA)。
临床怎么用
- 参与者可利用反馈报告中的sigma值和容差区间判断其正确度和不精密度是否满足预设分析性能规范。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. METHODS: Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. RESULTS: The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. CONCLUSIONS: By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.
引用
- Thelen MHM, Jansen RTP, Weykamp CW, et al. Expressing analytical performance from multi-sample evaluation in laboratory EQA. Clin Chem Lab Med. 2017. PMID: 28182577. doi:10.1515/cclm-2016-0970
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。