文献速递临床微生物分子诊断

Portrait Staph ID/R血培养panel多中心评价:快速鉴定葡萄球菌及检测mecA基因

Multicenter Evaluation of the Portrait Staph ID/R Blood Culture Panel for Rapid Identification of Staphylococci and Detection of the mecA Gene.
PubMed 文献 · J Clin Microbiol · 2017-01-25

该多中心前瞻性研究评估Portrait Staph ID/R血培养panel多重PCR assay,直接从阳性血培养瓶鉴定金黄色葡萄球菌、路邓葡萄球菌和葡萄球菌属并检测mecA基因。共测试765瓶Bactec瓶,与常规方法比较,经不一致分析后,葡萄球菌鉴定阳性符合率和阴性符合率分别为99.4%和99.9%,mecA检测分别为99.7%和99.2%。

要点

  • 该panel可同时鉴定金黄色葡萄球菌、路邓葡萄球菌和葡萄球菌属至属水平并检测mecA。
  • 鉴定阳性符合率99.4%、阴性符合率99.9%;mecA检测阳性符合率99.7%、阴性符合率99.2%。
  • 研究纳入765瓶革兰阳性球菌阳性血培养瓶,涵盖单微生物和33例多微生物培养。

核心结论

  • Portrait Staph ID/R血培养panel在阳性血培养瓶中鉴定葡萄球菌和检测mecA基因具有高符合率。

研究设计与样本

  • 前瞻性多中心研究,在3个临床中心测试765瓶Bactec瓶,结果与独立实验室常规生化及头孢西丁纸片法比较,不一致结果分别用rpoB基因测序和mecA基因测序解决。

主要发现

  • 共回收658株葡萄球菌分离株:金黄色葡萄球菌211株、路邓葡萄球菌3株、葡萄球菌属444株。
  • 经不一致分析后,葡萄球菌鉴定阳性符合率99.4%、阴性符合率99.9%。
  • 经不一致分析后,mecA检测阳性符合率99.7%、阴性符合率99.2%。

关键数值与推荐

  • 葡萄球菌鉴定阳性符合率99.4%,阴性符合率99.9%。
  • mecA检测阳性符合率99.7%,阴性符合率99.2%。

临床怎么用

  • 该panel可直接从阳性血培养瓶快速鉴定金黄色葡萄球菌、路邓葡萄球菌和葡萄球菌属并检测mecA,辅助血流感染病原学诊断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Bloodstream infections are a leading cause of morbidity and mortality in the United States and are associated with increased health care costs. We evaluated the Portrait Staph ID/R blood culture panel (BCP) multiplex PCR assay (Great Basin Scientific, Salt Lake City, UT) for the rapid and simultaneous identification (ID) of Staphylococcus aureus, Staphylococcus lugdunensis, and Staphylococcus species to the genus level and the detection of the mecA gene directly from a positive blood culture bottle. A total of 765 Bactec bottles demonstrating Gram-positive cocci in singles or clusters were tested during the prospective trial at 3 clinical sites. The Portrait Staph ID/R BCP results were compared with results from conventional biochemical and cefoxitin disk methods performed at an independent laboratory. Discordant ID and mecA results were resolved by rpoB gene sequencing and mecA gene sequencing, respectively. A total of 658 Staphylococcus species isolates (S. aureus, 211 isolates; S. lugdunensis, 3 isolates; and Staphylococcus spp., 444 isolates) were recovered from monomicrobial and 33 polymicrobial blood cultures. After discrepant analysis, the overall ratios of Portrait Staph ID/R BCP positive percent agreement and negative percent agreement were 99.4%/99.9% for Staphylococcus ID and 99.7%/99.2% for mecA detection.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Denys GA, Collazo-Velez V, Young S, et al. Multicenter Evaluation of the Portrait Staph ID/R Blood Culture Panel for Rapid Identification of Staphylococci and Detection of the mecA Gene. J Clin Microbiol. 2017. PMID: 28122871. doi:10.1128/JCM.02348-16

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。