Techcyte人工智能图像分析系统在临床粪便寄生虫诊断中的性能:一项回顾性评估研究
该研究回顾性分析178份临床粪便标本,比较Techcyte人工智能(AI)湿片碘液软件与常规显微镜检查对原虫和蠕虫感染的检测与鉴定效果。操作者审核后的AI判读总体阳性符合率为96.62%、阴性符合率为93.33%,kappa系数0.865;AI系统在74/178份(41.57%)标本中检出额外寄生虫。AI辅助镜检结合操作者审核可提升肠道寄生虫诊断流程的效率与一致性。
要点
- 操作者审核AI判读的总体PPA为96.62%、NPA为93.33%,与常规镜检高度一致(kappa=0.865)。
- AI系统在74/178份(41.57%)标本中检出额外寄生虫,显示诊断增益。
- AI辅助镜检需结合操作者审核,可作为筛查与补充工具。
核心结论
- AI辅助镜检结合操作者审核可提高肠道寄生虫诊断的可靠性,并在相当比例标本中带来诊断增益。
研究设计与样本
- 标本包括单一原虫/蠕虫感染阳性116份、混合感染阳性31份、阴性31份。
主要发现
- 操作者审核AI判读的总体阳性符合率(PPA)为96.62%,阴性符合率(NPA)为93.33%。
- AI判读与常规显微镜检查的kappa系数为0.865,提示高度一致。
- AI系统在74/178份(41.57%)标本中检出额外寄生虫。
关键数值与推荐
- 总体检测(操作者审核AI判读)PPA 96.62%、NPA 93.33%、kappa 0.865。
临床怎么用
- AI辅助镜检可作为临床微生物实验室粪便寄生虫筛查与常规诊断的补充工具,需结合操作者审核。
局限性
- 存在标本低体积分析限制与伪影检测问题。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Coproparasitological stool analysis based on microscopic examination is the reference diagnostic technique routinely performed in clinical microbiology laboratories. Automated image analysis systems could offer a suitable solution, reducing technologist workload and improving screening efficiency. The Human Fecal Ova & Parasite (O&P) Detection Solution (Techcyte) is an artificial intelligence (AI) software employing imaging-based algorithms to provide screening presumptive diagnostic results. This study aimed to validate the Wet Mount Iodine Solution software for detecting and diagnosing protozoan and helminthic infections in stool specimens. A total of 178 clinical stool specimens were retrospectively analyzed between July and October 2024 for comparative evaluation of the AI-based system. Positive specimens with confirmed mono (n = 116) and mixed (n = 31) protozoa and helminth infections, as well as negative specimens (n = 31), were included. Conventional microscopy results were compared with AI presumptive detection and identification outcomes. In addition, operator-reviewed AI results were evaluated against the reference diagnosis. The system achieved 96.62% positive percent agreement (PPA) and 93.33% negative percent agreement (NPA) for overall detection considering operator-reviewed interpretation. The kappa coefficient was 0.865, indicating strong agreement with conventional microscopy. The AI system detected additional parasites in 74/178 (41.57%) specimens, providing a diagnostic improvement compared to traditional microscopy. AI-assisted microscopy enhances intestinal parasite diagnosis, providing reliable results when combined with operator review. Despite limitations such as specimen low volume analysis and artifact detection, the system shows strong potential for improving diagnostic workflows in clinical microbiology laboratories. IMPORTANCE: Microscopic examination of stool specimens remains the reference technique for diagnosing intestinal parasitic infections although it is labor-intensive and operator-dependent methodology. The implementation of artificial intelligence-assisted microscopy offers a promising approach to streamline diagnostic workflows, improve consistency, and enhance traditional methods. Our evaluation study provides valuable clinical evaluation data of the Human Fecal Ova & Parasite (O&P) Detection Wet Mount Iodine Solution (Techcyte), demonstrating high sensitivity, specificity, and agreement with conventional microscopy. Importantly, AI-assisted review yielded diagnostic gains in a substantial proportion of specimens, underscoring its value as a screening and complementary tool for routine parasitological diagnostics. These findings highlight the potential of AI-powered image analysis to improve the accuracy and efficiency of coproparasitological testing, thereby supporting clinical decision-making and optimizing resource utilization in microbiology laboratories.
引用
- Rubio Maturana C, Sulleiro E, Zarzuela F, et al. Performance of the Techcyte AI-based image analysis system for coproparasitological diagnosis in clinical stool specimens: a retrospective evaluation study. J Clin Microbiol. 2026. PMID: 42324608. doi:10.1128/jcm.00431-26
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。