文献速递临床免疫分子诊断

多重微球免疫分析检测巴西东北部多种虫媒病毒感染/暴露

Identification of multiple arbovirus infections/exposure in Northeastern Brazil using a multiplex microsphere immunoassay.
PubMed 文献 · J Clin Microbiol · 2026-04-30

研究开发了使用13种抗原的多重IgG微球免疫分析(MIA),在374份有明确虫媒病毒感染或疫苗接种的样本中评估敏感性/特异性,并联合中和试验和免疫印迹检测巴西巴伊亚州Saúde镇300份血清。结果显示NS1-based MIA敏感性高但ZIKV和WNV NS1特异性低,当地人群多虫媒病毒血清阳性率高且多存在多重感染/暴露。

要点

  • 混合DENV1-4、ZIKV、WNV、YFV NS1及CHIKV VLP IgG MIA的敏感性/特异性分别为96.0%/98.3%、100%/79.9%、94.4%/73.4%、52.2%/94.4%、100%/99.7%。
  • ZIKV和WNV NS1总体特异性低,源于重复正黄病毒感染的交叉反应,包括二次DENV和DENV+ZIKV感染。
  • 在Saúde,DENV、ZIKV、YFV和CHIKV血清阳性率分别为70.3%、22.3%、39.7%和5.7%,多数存在多重虫媒病毒感染/暴露。

核心结论

  • 基于NS1的多重IgG MIA需确认试验,联合确认试验后可成为地方性流行区虫媒病毒血清诊断和血清监测的高通量工具。

研究设计与样本

  • 开发使用13种抗原的多重IgG微球免疫分析(MIA),测试8组有明确虫媒病毒感染或疫苗接种的样本(n=374)。
  • 联合先前报道的中和试验和免疫印迹分析,检测巴西巴伊亚州Saúde镇采集的血清样本(n=300)。

主要发现

  • 混合DENV1-4、ZIKV、WNV、YFV NS1和CHIKV VLP IgG MIA的敏感性/特异性分别为96.0%/98.3%、100%/79.9%、94.4%/73.4%、52.2%/94.4%、100%/99.7%。
  • ZIKV和WNV NS1总体特异性低,由重复正黄病毒感染(包括二次DENV和DENV+ZIKV感染)的交叉反应导致。
  • 在Saúde,DENV、ZIKV、YFV、CHIKV血清阳性率分别为70.3%、22.3%、39.7%、5.7%,多数存在多重虫媒病毒感染/暴露,包括DENV+CHIKV、DENV+ZIKV、DENV+YFV、DENV+ZIKV+YFV和/或CHIKV。

关键数值与推荐

  • 混合DENV1-4 NS1 IgG MIA敏感性/特异性:96.0%/98.3%。
  • ZIKV NS1 IgG MIA敏感性/特异性:100%/79.9%。
  • WNV NS1 IgG MIA敏感性/特异性:94.4%/73.4%。
  • YFV NS1 IgG MIA敏感性/特异性:52.2%/94.4%。
  • CHIKV VLP IgG MIA敏感性/特异性:100%/99.7%。

临床怎么用

  • 基于NS1的多重IgG MIA结果需用确认试验(如中和试验和免疫印迹)验证,尤其ZIKV和WNV NS1阳性时。
  • 该高通量 assay 联合确认试验可用于地方性流行区虫媒病毒感染的血清诊断和血清监测。

局限性

  • ZIKV和WNV NS1的总体特异性低,因重复正黄病毒感染(包括二次DENV和DENV+ZIKV感染)的交叉反应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Several mosquito-borne arboviruses, including dengue (DENV), Zika (ZIKV), West Nile (WNV), yellow fever (YFV), and chikungunya (CHIKV) viruses, have caused disease outbreaks of public health concern in the tropics and subtropics. The overlap distribution of these arboviruses and cross-reactivities of antibodies to orthoflavivirus envelope protein underscore the need for a reliable and convenient serological test to distinguish these arboviruses in endemic countries. We developed a multiplex IgG microsphere immunoassay (MIA) using 13 antigens to test 8 panels of samples with well-documented arbovirus infections or vaccination (n = 374). We further employed this assay, combined with previously reported neutralization test and Western blot analysis to test serum samples (n = 300) collected from Saúde, a town in the Northeastern state of Bahia, Brazil. The sensitivity/specificity of mixed DENV1-4, ZIKV, WNV, and YFV nonstructural protein 1 (NS1), and CHIKV virus-like particles (VLP) IgG MIAs were 96.0%/98.3%, 100%/79.9%, 94.4%/73.4%, 52.2%/94.4%, and 100%/99.7%, respectively. The overall low specificity of ZIKV and WNV NS1 was due to cross-reactivities from panels with repeated orthoflavivirus infections, including secondary DENV and DENV + ZIKV infections. In Saúde, we found seropositivity of 70.3%, 22.3%, 39.7%, and 5.7% to DENV, ZIKV, YFV, and CHIKV, respectively, and the majority with multiple arbovirus infections or exposure including DENV + CHIKV, DENV + ZIKV, DENV + YFV, DENV + ZIKV + YFV, and/or CHIKV. Our findings highlight the importance of confirmatory tests for the NS1-based multiplex IgG MIA. This high-throughput assay, combined with confirmatory tests, provides a labor-saving and validated tool for serodiagnosis and serosurveillance of pathogenic arbovirus infections/exposure in endemic regions.IMPORTANCESeveral multiplex microsphere immunoassays (MIA) have been reported to detect pathogenic arbovirus infections, including dengue (DENV), Zika (ZIKV), West Nile (WNV), yellow fever (YFV), and chikungunya (CHIKV) viruses. None of them included sufficient control panels to validate the sensitivity/specificity of each antigen, confirmatory tests for equivocal samples, or comparison with available commercial kits to advance this technology from research to practical use. We employed eight panels of samples with known arbovirus infections or vaccination (n = 374) to evaluate the sensitivity/specificity of our multiplex IgG MIA. We reported high sensitivity of nonstructural protein 1 (NS1)-based IgG MIA (94.4%-100% except YFV NS1) and overall low specificity of ZIKV and WNV NS1 due to cross-reactivities from repeated orthoflavivirus infections, including secondary DENV and DENV + ZIKV infections. Using our algorithm and confirmatory tests, we reported multiple arbovirus infections or exposure (DENV + ZIKV, DENV + YFV, DENV + ZIKV + YFV, and/or CHIKV) in the majority of participants from a town in Northeastern Brazil.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Wang W-K, Netto EM, Hsieh S-C, et al. Identification of multiple arbovirus infections/exposure in Northeastern Brazil using a multiplex microsphere immunoassay. J Clin Microbiol. 2026. PMID: 42060779. doi:10.1128/jcm.00013-26

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。