文献速递临床免疫临床血液与体液

两种快速免疫检测联合显著提高肝素诱导血小板减少症的诊断敏感性

A combination of 2 rapid immunoassays significantly improves diagnostic sensitivity for heparin-induced thrombocytopenia.
PubMed 文献 · Am J Clin Pathol · 2026-01-01

该回顾性观察研究纳入100例患者,以肝素诱导血小板聚集功能试验(HIPA)为参照,评估化学发光免疫分析(CLIA)、乳胶免疫比浊法(LIA)及两者联合的诊断性能。结果显示CLIA与LIA联合可实现27例真阳性、0例假阴性,当两种自动化检测均呈中或强阳性时敏感性达100%。

要点

  • CLIA与LIA联合检测可消除假阴性,提高诊断敏感性。
  • 两种自动化检测均呈中或强阳性时,联合检测敏感性达100%。
  • 单独LIA假阳性较多,联合CLIA可优化判读。

核心结论

  • CLIA与LIA联合检测具有高敏感性,随着检测反应性增高,检出血小板活化抗体的概率逐步增加,当两种自动化检测均呈中或强结果时敏感性达100%。

研究设计与样本

  • 观察性回顾研究,纳入100例患者,所有样本先在ACL TOP AcuStar上完成CLIA检测,随后在同一样本上于ACL TOP 970 CL上同时进行LIA和CLIA检测,并执行HIPA试验。

主要发现

  • CLIA在AcuStar和ACL TOP 970 CL上结果一致:68%患者阴性,32%阳性;HIPA确认32例阳性中的26例,识别6例假阳性和1例假阴性。
  • LIA在ACL TOP 970 CL上检测:64%患者阴性,36%阳性;HIPA确认24例阳性,识别12例假阳性和3例假阴性。
  • CLIA与LIA联合分类:27例真阳性、13例假阳性、0例假阴性、60例真阴性。

关键数值与推荐

  • CLIA与LIA联合检测:真阳性27例、假阳性13例、假阴性0例、真阴性60例。
  • CLIA单独检测:阴性68%、阳性32%,HIPA确认26例真阳性、6例假阳性、1例假阴性。
  • LIA单独检测:阴性64%、阳性36%,HIPA确认24例真阳性、12例假阳性、3例假阴性。

临床怎么用

  • 对于疑似肝素诱导血小板减少症(HIT)患者,可联合使用CLIA与LIA快速免疫检测以提高诊断敏感性。
  • 当CLIA与LIA均呈中或强阳性时,血小板活化抗体检出概率达100%,可支持临床决策。

局限性

  • 本研究为单中心回顾性观察研究,样本量100例,结果需进一步前瞻性验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate the diagnostic performance of chemiluminescent immunoassay (CLIA), latex immunoturbidimetric assay (LIA), and the combination of CLIA/LIA with respect to the functional heparin-induced platelet aggregation (HIPA) test. METHODS: An observational retrospective study was conducted on 100 patients. All samples were initially tested with CLIA on the ACL TOP AcuStar, and then we performed LIA and CLIA tests concurrently (on the same samples on the ACL TOP 970 CL) and the HIPA test. RESULTS: The CLIA test was performed on both the AcuStar and the ACL TOP 970 CL, and results were concordant: 68% of patients were negative, and 32% were positive. The HIPA test confirmed a diagnosis in 26 of 32 and identified 6 false-positive patients and 1 false-negative patient. The LIA test was performed on the ACL TOP 970 CL: 64% of patients were negative, and the remaining 36% were positive. The HIPA test confirmed a diagnosis in 24 patients and identified 12 false-positive and 3 false-negative patients. The combination of CLIA and LIA tests allowed us to categorize 27 true-positive, 13 false-positive, 0 false-negative, and 60 true-negative patients. CONCLUSIONS: The combination of CLIA/LIA provides high sensitivity with a progressively greater probability of detecting platelet-activating antibodies with a higher assay reactivity, reaching 100% when both automated assays yield moderate or strong results.

来源:Am J Clin Pathol,查看原文。版权归原作者所有。

引用

  1. Ciarrocca Taranta G, Rogolino A, Bertelli A, et al. A combination of 2 rapid immunoassays significantly improves diagnostic sensitivity for heparin-induced thrombocytopenia. Am J Clin Pathol. 2026. PMID: 41865396. doi:10.1093/ajcp/aqag016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。