储存条件对脑脊液和血清中NSE、S100及B2M稳定性的影响
该研究分析了63份脑脊液和56份血清儿科样本,评估-20°C与-80°C储存下NSE、S100和B2M的稳定性。结果显示NSE和S100在-20°C下显著降解,而B2M在所有条件下稳定,强调-80°C储存对保证生物标志物可靠性的必要性。
要点
- -20°C储存6个月后脑脊液NSE下降约74%,S100下降约71%。
- -20°C仅24小时脑脊液NSE即下降61%。
- -80°C储存12个月内NSE和S100下降均低于约15%。
核心结论
- 脑脊液NSE和S100在-20°C下极易降解,B2M相对稳定,严格遵循-80°C储存方案对保证生物标志物诊断和研究可靠性至关重要。
研究设计与样本
- 研究分析了63份脑脊液和56份血清儿科样本,分别于-20°C储存24小时和6个月、-80°C储存6和12个月。
- NSE和S100采用电化学发光免疫分析测定,B2M采用浊度免疫分析测定。
- 生物标志物变异性以相对基线百分比变化表示,脑脊液最大允许误差为±15%,血清为±10%。
主要发现
- 脑脊液储存6个月后NSE下降约74%,S100下降约71%;血清NSE下降约54%,S100下降约13%。
- 脑脊液在-20°C仅24小时后NSE即下降61%。
- -80°C储存12个月内NSE和S100下降均低于约15%。
- B2M在所有储存条件下保持稳定。
- 脑脊液NSE在-20°C下的下降与基线浓度强相关。
关键数值与推荐
- 脑脊液最大允许误差为±15%,血清为±10%。
- 脑脊液NSE在-20°C储存6个月后下降约74%,24小时后下降61%。
- 脑脊液S100在-20°C储存6个月后下降约71%。
- 血清NSE在-20°C储存6个月后下降约54%,S100下降约13%。
- -80°C储存12个月内NSE和S100下降均低于约15%。
临床怎么用
- 脑脊液和血清中NSE、S100的检测样本应严格储存于-80°C以保证结果可靠性。
- B2M对储存条件要求相对宽松,在-20°C和-80°C下均稳定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The reliability of cerebrospinal fluid (CSF) and serum biomarkers depends on sample integrity, which is strongly influenced by storage conditions. While -80 °C is considered the gold standard for long-term preservation, it requires specialized infrastructure, whereas -20 °C is more accessible but may compromise protein stability. This study aimed to evaluate the stability of three clinically relevant biomarkers - neuron-specific enolase (NSE), S100, and β-2 microglobulin (B2M), associated with neuronal injury and neuroinflammation - in CSF and serum samples stored at -20 °C and -80 °C over different time periods. METHODS: A total of 63 CSF and 56 serum samples from pediatric patients were analyzed. Samples were stored at -20 °C (24 h and 6 months) and -80 °C (6 and 12 months). NSE and S100 were measured by electrochemiluminescence immunoassays and B2M by turbidimetric immunoassay. Biomarker variability was expressed as relative percentage change from baseline. A maximum permissible error of ±15 % for CSF and ±10 % for serum was selected. RESULTS: NSE and S100 were highly unstable at -20 °C. In CSF, after 6 months, NSE decreased by ∼74 % and S100 by ∼71 %; in serum, NSE declined by ∼54 % and S100 by ∼13 %. Remarkably, after only 24 h at -20 °C, CSF NSE dropped by 61 %. Storage at -80 °C largely preserved these two biomarkers, with declines below ∼15 % over 12 months. B2M levels remained stable under all conditions. The reduction in CSF NSE at -20 °C was strongly correlated with baseline concentrations. CONCLUSIONS: CSF biomarkers NSE and S100 are highly susceptible to degradation at -20 °C, whereas B2M remains relatively stable. Strict adherence to -80 °C storage protocols is essential to ensure the reliability of biomarker-based diagnostics and research.
引用
- García-Sancha N, Valencia J, Gundín S, et al. Effect of storage conditions on NSE, S100, and B2M stability in cerebrospinal fluid and serum. Clin Chem Lab Med. 2026. PMID: 41591274. doi:10.1515/cclm-2025-1320
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。