平衡透析同位素稀释液相色谱串联质谱法测定血清游离甲状腺激素的候选参考方法
本研究基于同位素稀释液相色谱串联质谱(ID-LC-MS/MS)技术,利用可重复使用的平衡透析装置分离血清游离甲状腺激素,建立了同时定量FT3和FT4的候选参考测量程序(cRMP),并进行了系统验证、方法比较和不确定度评估。该方法定量下限为FT3 1.54 pmol/L、FT4 3.22 pmol/L,不精密度小于3%,未观察到内源性类似物干扰,室间比对一致性良好;而化学发光免疫法结果与cRMP一致性差。
要点
- 建立的ID-LC-MS/MS候选参考方法可同时准确定量血清FT3和FT4。
- 方法定量下限FT3为1.54 pmol/L、FT4为3.22 pmol/L,不精密度小于3%。
- 化学发光免疫法与候选参考方法结果一致性差,提示常规检测标准化需求。
核心结论
- 成功建立高精度、高准确度、高特异性和高灵敏度的ID-LC-MS/MS候选参考方法,可同时测定人血清FT3和FT4,为常规甲状腺功能检测标准化提供可靠工具。
研究设计与样本
- 方法学研究:采用可重复使用的平衡透析装置分离血清游离甲状腺激素,优化温度、pH、膜类型和透析时间等参数,透析液直接经ID-LC-MS/MS定量。
- 对建立的方法进行系统验证、与现有检测方法比较分析及全面不确定度评估。
主要发现
- 候选参考方法定量下限为FT3 1.54 pmol/L、FT4 3.22 pmol/L,不精密度小于3%。
- 未观察到内源性类似物干扰,室间比对一致性良好。
- 化学发光免疫法结果与候选参考方法一致性差。
关键数值与推荐
- FT3定量下限1.54 pmol/L,FT4定量下限3.22 pmol/L。
- 方法不精密度小于3%。
临床怎么用
- 该候选参考方法可用于标准化常规甲状腺功能检测,并作为常规免疫分析法结果准确性的比对参考。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Free triiodothyronine (FT3) and free thyroxine (FT4) are important diagnostic markers for assessing thyroid function. However, their accurate quantification remains challenging due to low serum concentrations. Significant variability exists among current assay methods for measuring FT3 and FT4. This study aims to establish a candidate Reference Measurement Procedure (cRMP) for simultaneous quantification of serum FT3 and FT4 based on isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) technology. METHODS: A convenient and reusable equilibrium dialysis (ED) device was utilized to separate free thyroid hormones from their protein-bound counterparts in serum. Key dialysis parameters, including temperature, pH, membrane type, and duration, were optimized to ensure consistent and reliable performance. The dialysate containing FT3 and FT4 was directly quantified by ID-LC-MS/MS. The method underwent systematic validation, comparative analysis with existing assays, and a comprehensive uncertainty assessment. RESULTS: The developed cRMP demonstrated limits of quantification (LoQ) of 1.54 pmol/L for FT3 and 3.22 pmol/L for FT4, and with an imprecision of less than 3 %. No interference from endogenous analogs was observed, and the method showed good consistency in interlaboratory comparison. In contrast, chemiluminescent immunoassay results exhibited poor agreement with and the cRMP. CONCLUSIONS: This study developed a highly precise, accurate, specific, and sensitive ID-LC-MS/MS-based cRMP for the simultaneous measurement of FT3 and FT4 in human serum. This method provides a reliable tool for standardizing routine thyroid function tests.
引用
- Zhan M, Zhang Q, Ma Z, et al. Development and validation of a candidate reference measurement procedure for free triiodothyronine and free thyroxine in human serum using equilibrium dialysis isotope-dilution liquid chromatography-tandem mass spectrometry. Clin Chem Lab Med. 2025. PMID: 41405951. doi:10.1515/cclm-2025-0874
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。