文献速递临床生化临床免疫

新型免疫沉淀靶向液相色谱-串联质谱法准确测定人血清和肽素

A novel immunoprecipitation-based targeted liquid chromatography-tandem mass spectrometry analysis for accurate determination for copeptin in human serum.
PubMed 文献 · Clin Chem Lab Med · 2025-07-10

研究建立并验证了基于免疫沉淀的靶向LC-MS/MS法测定人血清和肽素,运行时间8.5分钟,批内精密度5.2-12.1%,总CV 8.1-13.5%,线性范围5-1000 pg/mL,检出限2.5 pg/mL。该方法与免疫荧光法一致性良好(r=0.926,斜率=0.989),健康人群参考区间3.66-58.25 pg/mL。

要点

  • LC-MS/MS法测定和肽素精密度好、线性范围宽、检出限低。
  • 与B.R.A.H.M.S平台免疫荧光法一致性良好(r=0.926)。
  • 健康人群参考区间为3.66-58.25 pg/mL。

核心结论

  • 该靶向LC-MS/MS法测定人血清和肽素准确可靠,精密度满意、线性范围宽且检出限低。

研究设计与样本

  • 研究采用免疫沉淀提取血清和肽素,经胰蛋白酶消化和阴离子交换固相萃取后行LC-MS/MS检测。
  • 分析性能按现行指南验证,并与B.R.A.H.M.S平台免疫荧光法进行比较。

主要发现

  • LC-MS/MS法运行时间为8.5分钟。
  • 批内精密度范围为5.2-12.1%,总变异系数范围为8.1-13.5%。
  • 和肽素定量在5-1000 pg/mL范围内呈线性,检出限为2.5 pg/mL。
  • 回收率范围为95.2-103.1%,经内标校正后未观察到显著基质效应。
  • LC-MS/MS法与免疫分析法一致性良好(r=0.926,斜率=0.989)。

关键数值与推荐

  • 批内精密度5.2-12.1%,总CV 8.1-13.5%。
  • 线性范围5-1000 pg/mL,检出限2.5 pg/mL。
  • 回收率95.2-103.1%,内标校正后无显著基质效应。
  • 与免疫法一致性r=0.926,斜率=0.989。
  • 健康个体参考区间3.66-58.25 pg/mL。

临床怎么用

  • 该法可用于人血清和肽素的准确定量,尤其适用于多尿-多饮综合征的诊断场景。
  • 尚需临床研究评估该方法的诊断准确性。

局限性

  • 尚需开展临床研究评估该方法的诊断准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Copeptin, a stable and simple-to-measure surrogate marker for arginine vasopressin (AVP), demonstrates excellent clinical values, particularly in diagnosing polyuria-polydipsia syndromes. However, conventional immunoassay methods are limited and lack comparability. Our aim was to establish a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying copeptin in human serum. METHODS: Copeptin was extracted from serum using immunoprecipitation, digested with trypsin, and prepared using anion exchange solid-phase extraction before LC-MS/MS detection. The analytical performance was validated in accordance with current guidelines. The method was compared to an immunofluorescent assay on the B.R.A.H.M.S platform. RESULTS: The LC-MS/MS method had a runtime of 8.5 min. The within-run precision ranged from 5.2 to 12.1 %, and total coefficients of variation ranged from 8.1 to 13.5 %. Copeptin quantitation showed linearity within the range of 5-1,000 pg/mL, with a limit of detection of 2.5 pg/mL. Recovery rates ranged from 95.2 to 103.1 %, and no significant matrix effect was observed with internal standard correction. The LC-MS/MS method had a good consistency with the immunoassay (r=0.926, slope=0.989). The reference interval for healthy individuals was 3.66-58.25 pg/mL. CONCLUSIONS: We demonstrated the accuracy and reliability of this targeted LC-MS/MS method for quantifying copeptin. This innovative application showed satisfactory precision, a wide linear range, and a low limit of detection. Clinical studies are anticipated to be conducted to assess diagnostic accuracy using this method.

来源:Clin Chem Lab Med,查看原文。版权归原作者所有。

引用

  1. Mu D, Ma X, Ma Y, et al. A novel immunoprecipitation-based targeted liquid chromatography-tandem mass spectrometry analysis for accurate determination for copeptin in human serum. Clin Chem Lab Med. 2025. PMID: 40632715. doi:10.1515/cclm-2025-0022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。